Fast IR array detector for transverse beam diagnostics at DA¦NE (Contributo in atti di convegno)

Type
Label
  • Fast IR array detector for transverse beam diagnostics at DA¦NE (Contributo in atti di convegno) (literal)
Anno
  • 2010-01-01T00:00:00+01:00 (literal)
Alternative label
  • Bocci A., Cloazza A., Drago A., Grilli A., Marcelli A., Cestelli Guidi M., Raco A., Sorchetti R., Gambicorti L., De Sio A., Pace E., Piotrowsky J. (2010)
    Fast IR array detector for transverse beam diagnostics at DA¦NE
    in International Particle Accelerator Conference (IPAC'10), Kyoto, Japan
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Bocci A., Cloazza A., Drago A., Grilli A., Marcelli A., Cestelli Guidi M., Raco A., Sorchetti R., Gambicorti L., De Sio A., Pace E., Piotrowsky J. (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#descrizioneSinteticaDelProdotto
  • At the LNF of INFN an IR array de­tec­tor with a ns re­sponse time has been built and as­sem­bled in order to col­lect the IR image of the e-/e+ sources at DA¦NE. Such de­tec­tor is made by 32 bi­lin­ear pix­els with a pixel size of 50x50 ¼m2 and a re­sponse time of 1 ns. The de­vice with its elec­tron­ic board has been as­sem­bled for the in­stal­la­tion on the e+ ring of DA¦NE in the frame­work of an ex­per­i­ment fund­ed by the INFN Vth Com­mit­tee ded­i­cat­ed to beam di­ag­nos­tics. A pre­lim­i­nary char­ac­ter­i­za­tion of few pix­els of the array and of the elec­tron­ics has been car­ried out at the IR beam­line SIN­BAD at DA¦NE. In par­tic­u­lar the de­tec­tion of the IR source of the e- beam has been ob­served using four pix­els of the array ac­quir­ing sig­nals si­mul­ta­ne­ous­ly with a 4 chan­nels scope at 1GHz and at 4 Gsam­ples/s. The ac­qui­si­tion of 4 pix­els al­lowed mon­i­tor­ing in real time dif­fer­ences in the bunch sig­nals in the ver­ti­cal di­rec­tion. Pre­lim­i­nary anal­y­sis of data is pre­sent­ed and dis­cussed. In par­tic­u­lar we will out­line how the dif­fer­ences in the sig­nals can be cor­re­lat­ed to small dis­place­ments of the source after the bunch re­fill­ing and dur­ing a com­plete shift of DA¦NE and be­fore the re­fill­ing of elec­trons. (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Centro National de Aceleradores, University of Seville, C/Thomas Alva Edison 7, 41092 Seville, Spain; INFN – Laboratori Nazionali di Frascati, Via Enrico Fermi 40, I-00044 Frascati RM, Italy; CNR - Itituto Nazionale di Ottica, Largo Fermi 6, 50125 Firenze, Italy; Università degli Studi di Firenze, Largo Fermi 2, 50125 Firenze, Italy VIGO System SA, 3 Swietlikow Str. 01-389 Warsaw, Poland (literal)
Titolo
  • Fast IR array detector for transverse beam diagnostics at DA¦NE (literal)
Prodotto di