http://www.cnr.it/ontology/cnr/individuo/prodotto/ID95424
Direct Torque Control for 3-Level Fed Induction Motor Drives with Capacitor Voltage Ripple Minimization (Contributo in atti di convegno)
- Type
- Label
- Direct Torque Control for 3-Level Fed Induction Motor Drives with Capacitor Voltage Ripple Minimization (Contributo in atti di convegno) (literal)
- Anno
- 2008-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1109/IECON.2008.4758479 (literal)
- Alternative label
M. Cirrincione, M. Pucci, G. Vitale (2008)
Direct Torque Control for 3-Level Fed Induction Motor Drives with Capacitor Voltage Ripple Minimization
in 34th Annual Conference of the IEEE Industrial Electronics Society, IECON-2008. 10-13 November 2008, Orlando, FL, 10-13 Nov. 2008
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- M. Cirrincione, M. Pucci, G. Vitale (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://ieeexplore.ieee.org/xpl/articleDetails.jsp?tp=&arnumber=4758479&contentType=Conference+Publications&matchBoolean%3Dtrue%26searchField%3DSearch_All%26queryText%3D%28%28%28p_Title%3Adirect%29+AND+p_Title%3Atorque%29+AND+p_Authors%3Avitale%29 (literal)
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#descrizioneSinteticaDelProdotto
- This paper presents a new ST-DTC control algorithm
for three-level NPC inverter fed induction machine drives. It is
an improvement of a previous ST-DTC technique for 3-level
inverters, which has been further improved in the following
aspects: 1) it employs all the 18 active voltage vectors of the
inverter hexagon, including the medium ones, whereas the
previous one adopted only 12 voltage vectors. 2) it performs the
torque control on the basis of three torque demand levels
(instead of two), respectively big, average and small. 3) it
employs a new closed-loop neutral point voltage balancing
algorithm, which permits the DC link capacitor divider to share
the DC link voltage, whatever voltage vector is used (even the
medium ones). The proposed ST-DTC control technique has
been verified experimentally on a properly devised test setup.
The new neutral point voltage balancing technique proved to
work properly also using medium voltage vectors, both in loaded
and unloaded conditions. (literal)
- Note
- Scopus (literal)
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- ISSIA-CNR (Institute on Intelligent Systems for the
Automation)
Université de Technologie de Belfort-Montbéliard (UTBM) (literal)
- Titolo
- Direct Torque Control for 3-Level Fed Induction Motor Drives with Capacitor Voltage Ripple Minimization (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
- 978-1-4244-1766-7 (literal)
- Abstract
- This paper presents a new ST-DTC control algorithm
for three-level NPC inverter fed induction machine drives. It is
an improvement of a previous ST-DTC technique for 3-level
inverters, which has been further improved in the following
aspects: 1) it employs all the 18 active voltage vectors of the
inverter hexagon, including the medium ones, whereas the
previous one adopted only 12 voltage vectors. 2) it performs the
torque control on the basis of three torque demand levels
(instead of two), respectively big, average and small. 3) it
employs a new closed-loop neutral point voltage balancing
algorithm, which permits the DC link capacitor divider to share
the DC link voltage, whatever voltage vector is used (even the
medium ones). The proposed ST-DTC control technique has
been verified experimentally on a properly devised test setup.
The new neutral point voltage balancing technique proved to
work properly also using medium voltage vectors, both in loaded
and unloaded conditions. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di