Carbon paste electrode bulk modified with a conducting polymer poly(1,8-diaminonaphthalene): application to lead determination (Articolo in rivista)

Type
Label
  • Carbon paste electrode bulk modified with a conducting polymer poly(1,8-diaminonaphthalene): application to lead determination (Articolo in rivista) (literal)
Anno
  • 2003-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1007/s00604-003-0058-5 (literal)
Alternative label
  • SanaĆ¢. Majid , Mamia El Rhazi , Aziz. Amine , Antonella Curulli , Giuseppe Palleschi (2003)
    Carbon paste electrode bulk modified with a conducting polymer poly(1,8-diaminonaphthalene): application to lead determination
    in Mikrochimica acta (1966, Print); Springer, New York (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • SanaĆ¢. Majid , Mamia El Rhazi , Aziz. Amine , Antonella Curulli , Giuseppe Palleschi (literal)
Pagina inizio
  • 195 (literal)
Pagina fine
  • 204 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 143 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 10 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopu (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Univ Hassan II, Fac Sci & Tech, Mohammadia, Morocco Ist Studio Mat Nanostrutturati, Sez Roma 2, CNR ISMN, I-00161 Rome, Italy Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy (literal)
Titolo
  • Carbon paste electrode bulk modified with a conducting polymer poly(1,8-diaminonaphthalene): application to lead determination (literal)
Abstract
  • Carbon paste electrodes modified with conducting polymers for sensitive and selective determination of lead are presented. A novel method for generating a reproducible polymer-coated electrode surface is developed. We prove that 1,8-diaminonaphthalene (1,8-DAN) mixed with a carbon paste electrode leads to a conducting polymer in acidic medium while, in the same medium, this polymer is known to be non-conducting on platinum electrode. The electrode behaviour of poly(1,8-DAN), electropolymerised into carbon paste, was investigated by cyclic voltammetry in the presence of the ferri-ferrocyanide couple. A carbon paste electrode modified with poly(1,8-DAN) was used to determine Pb2+ in aqueous solutions. Pb2+ ions were firstly complexed and then electrochemically deposited by a potential step to -0.9 V. The accumulated lead after reduction was anodically stripped by differential pulse voltammetry. Different parameters, such as pH of the solution, preconcentration time, and electropolymerisation procedures were studied. For a preconcentration time of ten minutes, the calibration graph was linear from 40 to 2070 ng mL(-1) with r(2)=0.998. The detection limit was found to be 30 ng mL(-1), and the relative standard deviation was 6%. (literal)