http://www.cnr.it/ontology/cnr/individuo/prodotto/ID62966
Calibration methods for ITER core LIDAR (Articolo in rivista)
- Type
- Label
- Calibration methods for ITER core LIDAR (Articolo in rivista) (literal)
- Anno
- 2010-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1088/1742-6596/227/1/012044 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Pasqualotto R.; Giudicotti L.; Alfier A.; Walsh M.J. (literal)
- Pagina inizio
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- Article Number: 012044
La rivista è pubblicata anche online con ISSN 1742-6596. (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://iopscience.iop.org/1742-6596/227/1/012044/ (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- Scopu (literal)
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1,2,3 : Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, 35127 Padova, Italy / -
2 : Padova University, Electrical Engineering Department, Via Gradenigo 6/A, 35131 Padova, Italy / -
4 : EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon OX14 3DB, United
Kingdom. (literal)
- Titolo
- Calibration methods for ITER core LIDAR (literal)
- Abstract
- The standard technique for the relative calibration in present Thomson scattering diagnostics, can be used in ITER only if the full collection path is included in the calibration: indeed, the in-vessel optics will be exposed to neutron and gamma irradiation and particle flux, that will likely cause a distortion of the spectral transmission curve. The standard scheme would ask to position a diffuser in front of the first collection mirror, e.g. on the protective shutter, and to illuminate it with a light source nearby. Alternatively, a back illumination scheme could be used, with a more efficient retroreflector array. A completely different approach is based on TS measurements from two lasers with different wavelengths: this self-calibrating method does not require any in-vessel tool and will provide both the electron temperature and the relative sensitivity of spectral channels. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di