Edge Thomson Scattering in RFX-mod: operation and first measures (Articolo in rivista)

Type
Label
  • Edge Thomson Scattering in RFX-mod: operation and first measures (Articolo in rivista) (literal)
Anno
  • 2010-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1088/1742-6596/227/1/012030 (literal)
Alternative label
  • Alfier A.; Fassina A.; Pasqualotto R.; Dal Bello S.; Cervaro V.; Lotto L.; Tollin M. (2010)
    Edge Thomson Scattering in RFX-mod: operation and first measures
    in Journal of physics. Conference series (Print); IOP PUBLISHING LTD, BRISTOL BS1 6BE (Regno Unito)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Alfier A.; Fassina A.; Pasqualotto R.; Dal Bello S.; Cervaro V.; Lotto L.; Tollin M. (literal)
Pagina inizio
  • 012030 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • Article Number: 012030. La rivista è pubblicata anche online con ISSN 1742-6596. (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://iopscience.iop.org/1742-6596/227/1/012030/ (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 227 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 4 (literal)
Note
  • Scopu (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Consorzio RFX, Corso Stati Uniti 4, 35157 Padova (literal)
Titolo
  • Edge Thomson Scattering in RFX-mod: operation and first measures (literal)
Abstract
  • During the 2009 experimental campaign the Edge Thomson Scattering System started the operations, after a commissioning period. The main modification has been the adoption of interferential filters spectrometers with APD detectors, similar to those used on the main TS. Other improvements were the optimization of the laser input path and of the collection optics, which increased the signal level of about 50 %. With the present setup, temperature and density measures show good compatibility with those of the main TS diagnostic; density data have been calculated after Rotational Raman Scattering calibration, a method which is not affected by impurity deposition on the collection window. Present operational limits of the diagnostic are discussed as well as short terms planned operations, focusing in particular on laser multi-pulse issues and laser sharing with the impurity injection system by laser blow-off. (literal)