Measuring the refractive index of vitreous materials at cryogenic temperatures with a spectrometer (Articolo in rivista)

Type
Label
  • Measuring the refractive index of vitreous materials at cryogenic temperatures with a spectrometer (Articolo in rivista) (literal)
Anno
  • 2008-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1088/0957-0233/19/8/085304 (literal)
Alternative label
  • Maurizio Vannoni; Iacopo Mochi; Monica Olivieri; Giuseppe Mondello; Giuseppe Molesini (2008)
    Measuring the refractive index of vitreous materials at cryogenic temperatures with a spectrometer
    in Measurement science & technology (Print)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Maurizio Vannoni; Iacopo Mochi; Monica Olivieri; Giuseppe Mondello; Giuseppe Molesini (literal)
Pagina inizio
  • 085304-1 (literal)
Pagina fine
  • 085304-9 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://iopscience.iop.org/0957-0233/19/8/085304/ (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 19 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 9 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 8 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Google Scholar (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR, Istituto Nazionale di Ottica Applicata, Largo E Fermi 6, Firenze 50125, Italy; Istituto Nazionale di Astrofisica, Osservatorio Astrofisico di Arcetri, Largo E Fermi 5, Firenze 50125,Italy; Galileo Avionica, Via A Einstein 35, Campi Bisenzio 50013, Italy (literal)
Titolo
  • Measuring the refractive index of vitreous materials at cryogenic temperatures with a spectrometer (literal)
Abstract
  • The use of a spectrometer to measure the refractive index of a prism glass sample in the visible and near-infrared regions at cryogenic temperature is reported. The details of the measuring cell and the experimental apparatus are provided, and a specific data reduction procedure based on ray tracing is introduced. Demonstrative results on a BK7 prism sample in a temperature range from 105 to 293 K and wavelength from 480 to 894 nm are presented. The measurement uncertainty is 3 × 10^-5 (2?). (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it