http://www.cnr.it/ontology/cnr/individuo/prodotto/ID55242
A new portable XRF Spectrometer with a Beam Stability Control (Articolo in rivista)
- Type
- Label
- A new portable XRF Spectrometer with a Beam Stability Control (Articolo in rivista) (literal)
- Anno
- 2005-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1002/xrs.785 (literal)
- Alternative label
F. P. Romano; G. Calvi; E. Furia; S. Garraffo; C. Marchetta; G. Pappalardo; L. Pappalardo; F. Rizzo; A. Rovelli (2005)
A new portable XRF Spectrometer with a Beam Stability Control
in X-Ray Spectrometry; John Wiley & Sons, Ltd., Chichester (Regno Unito)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- F. P. Romano; G. Calvi; E. Furia; S. Garraffo; C. Marchetta; G. Pappalardo; L. Pappalardo; F. Rizzo; A. Rovelli (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- The spectrometer has been realised in the framework of the Agenzia 2000 project funded by Italian CNR (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1 INFN, Laboratori Nazionali del Sud, LANDIS, Via S. Sofia 44, 95123 Catania, Italy
2 CNR, Sezione di Catania dell'Istituto per i Beni Archeologici e Monumentali, Via A. di Sangiuliano 62, 95100 Catania, Italy
3 Universita` di Catania, Dipartimento di Fisica e Astronomia, Viale A. Doria 6, 95123 Catania, Italy
4 CNR, Istituto per le Tecnologie Applicate ai Beni Culturali, Via Salaria Km. 29,3 Montelibretti, 00016 Rome, Italy (literal)
- Titolo
- A new portable XRF Spectrometer with a Beam Stability Control (literal)
- Abstract
- A new portable XRF spectrometer which allows control of the energy and the intensity stability of the
emitted x-raybeamhasbeen designed and built. The control is obtained by measuring the x-ray fluorescence
generated by a double Ag/Ba thin target when crossed by the x-ray beam during a measurement. The
silver and barium fluorescence K lines are detected by an ancillary Si-PIN detector and analysed by
software developed at the LNS/INFN laboratories. The new portable spectrometer, the beam stability
control method, the evaluation of the system and some quantitative applications of interest in the cultural
heritage field are presented and discussed. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di