Simulation and laboratory experimental tests of a line to shield medium voltage power line communication system (Articolo in rivista)

Type
Label
  • Simulation and laboratory experimental tests of a line to shield medium voltage power line communication system (Articolo in rivista) (literal)
Anno
  • 2011-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1109/TPWRD.2011.2166813 (literal)
Alternative label
  • A. Cataliotti, C. Cosentino, D. Di Cara, G. Tinè (2011)
    Simulation and laboratory experimental tests of a line to shield medium voltage power line communication system
    in IEEE transactions on power delivery; IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 445 HOES LANE,, PISCATAWAY, NJ 08855-4141 (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • A. Cataliotti, C. Cosentino, D. Di Cara, G. Tinè (literal)
Pagina inizio
  • 2829 (literal)
Pagina fine
  • 2836 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • Q1 (Quartile secondo fonte SCImago) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6026242&tag=1 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 26 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 8 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 4 (literal)
Note
  • Scopu (literal)
  • Google Scholar (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Università di Palermo; ISSIA-CNR (literal)
Titolo
  • Simulation and laboratory experimental tests of a line to shield medium voltage power line communication system (literal)
Abstract
  • A complete model of a power-line communication (PLC) system on a medium-voltage (MV) network in the case of a line-shield configuration is presented in this paper. An MV cable model in a line-shield configuration is considered together with the power transformers, the signal coupling networks, and the receiving and transmitting line coupling interface of a ST7540 FSK power-line transceiver. Simulations of the complete model of the system under consideration have been carried out for different line lengths, with and without power transformers and derivation branches. The model is validated by experimental tests performed in the laboratory. The measured results confirm the reliability of the model. (literal)
Editore
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
Insieme di parole chiave di
data.CNR.it