http://www.cnr.it/ontology/cnr/individuo/prodotto/ID52548
A New Direct Torque Control Strategy for the Minimization of Common Mode Emissions (Articolo in rivista)
- Type
- Label
- A New Direct Torque Control Strategy for the Minimization of Common Mode Emissions (Articolo in rivista) (literal)
- Anno
- 2006-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1109/TIA.2005.863907 (literal)
- Alternative label
M. Cirrincione, M. Pucci, G. Vitale, G. Cirrincione (2006)
A New Direct Torque Control Strategy for the Minimization of Common Mode Emissions
in IEEE transactions on industry applications
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- M. Cirrincione, M. Pucci, G. Vitale, G. Cirrincione (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1608229 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- Scopus (literal)
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- CNR - ISSIA UOS di Palermo (literal)
- Titolo
- A New Direct Torque Control Strategy for the Minimization of Common Mode Emissions (literal)
- Abstract
- Abstract--This paper presents a new direct torque control
(DTC) algorithm for induction machine drives capable of reducing
the common-mode conducted emissions of the drive. It is based
on the application of only odd or only even voltage vectors in
each sector in which the stator flux lies. In the work, after an
overview of the generation of common-mode emissions of inverter
fed drives and the most employed techniques for their minimization,
a simplified equivalent circuit of the common-mode path has
been identified to be used in numerical simulation on the basis
of experimental measurements. Then, the new DTC technique
has been described and applied to an induction machine drive,
both in numerical simulation and experimentally on a suitably
developed test setup. Finally, results are presented and compared
to those obtained with the classic DTC technique. It has been
shown that this methodology is able to reduce the common-mode
voltage repetition rate, and therefore the resulting common-mode
currents in comparison with the classic DTC in a frequency range
of about tens of kilohertz. Finally the analysis of the impact of both
control techniques in terms of the current absorbed by the grid has
been performed. (literal)