Scanning near-field optical microscopy images of microradiographs stored in lithium fluoride films with an optical resolution of lambda/12 (Articolo in rivista)

Type
Label
  • Scanning near-field optical microscopy images of microradiographs stored in lithium fluoride films with an optical resolution of lambda/12 (Articolo in rivista) (literal)
Anno
  • 2006-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.2193654 (literal)
Alternative label
  • Ustione A.1; Cricenti A.1,2; Bonfigli F.3; Flora F.3; Lai A.3; Marolo T.3; Montereali R.M.3; Baldacchini G.3; Faenov A.4; Pikuz T.4; Reale L.5 (2006)
    Scanning near-field optical microscopy images of microradiographs stored in lithium fluoride films with an optical resolution of lambda/12
    in Applied physics letters
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Ustione A.1; Cricenti A.1,2; Bonfigli F.3; Flora F.3; Lai A.3; Marolo T.3; Montereali R.M.3; Baldacchini G.3; Faenov A.4; Pikuz T.4; Reale L.5 (literal)
Pagina inizio
  • 141107 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 88 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 14 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1 Istituto di Struttura della Materia--C.N.R., Roma, Italy; 2 Department of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee 37212 3 ENEA, Advanced Physical Technologies, C. R. Frascati, Italy 4 MISDC of VNIIFTRI Mendeleevo, Moscow Region, 141570, Russia 5 Università de L'Aquila e INFN, Physics Department, Coppito, 67100 L'Aquila, Italy (literal)
Titolo
  • Scanning near-field optical microscopy images of microradiographs stored in lithium fluoride films with an optical resolution of lambda/12 (literal)
Abstract
  • Here we show a new, simple method to observe soft x-ray microradiographs of biological material. A thin film of lithium fluoride (LiF) works as image detector, storing the microradiograph obtained exposing biological samples to extreme ultraviolet and soft x-ray radiations. To read the stored image, collecting the optically stimulated visible luminescence emitted by the LiF active color centers locally produced by the x rays, a scanning near-field optical microscope is used with an optical aperture of 50 nm, i.e., L/12, where L is the wavelength of the collected photoluminescence. (literal)
Prodotto di
Autore CNR

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
data.CNR.it