http://www.cnr.it/ontology/cnr/individuo/prodotto/ID48341
Sieve-based device for MALDI sample preparation. I. Influence of sample deposition conditions in oligonucleotide analysis to achieve significant increases in both sensitivity and resolution (Articolo in rivista)
- Type
- Label
- Sieve-based device for MALDI sample preparation. I. Influence of sample deposition conditions in oligonucleotide analysis to achieve significant increases in both sensitivity and resolution (Articolo in rivista) (literal)
- Anno
- 2008-01-01T00:00:00+01:00 (literal)
- Alternative label
Molin, L.; Cristoni, S.; Crotti, S.; Bernardi, L. R.; Seraglia, R.; Traldi, P. (2008)
Sieve-based device for MALDI sample preparation. I. Influence of sample deposition conditions in oligonucleotide analysis to achieve significant increases in both sensitivity and resolution
in Journal of mass spectrometry (Print)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Molin, L.; Cristoni, S.; Crotti, S.; Bernardi, L. R.; Seraglia, R.; Traldi, P. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
- DOI: 10.1002/jms.1428 (literal)
- Note
- ISI Web of Science (WOS) (literal)
- Titolo
- Sieve-based device for MALDI sample preparation. I. Influence of sample deposition conditions in oligonucleotide analysis to achieve significant increases in both sensitivity and resolution (literal)
- Abstract
- Spraying of oligonucleotide-matrix solutions through a stainless steel (ss) sieve (38 mu m, 450 mesh) leads to the formation, on the matrix-assisted laser desorption/ionization (MALDI) sample holder, of uniformly distributed microcrystals, well separated from each other. When the resulting sample holder surface is irradiated by laser, abundant molecular species form, with a clear increase in both intensity and resolution with respect to values obtained by 'Dried Droplet', 'Double Layer', and 'Sandwich' deposition methods. In addition, unlike the usual situation, the sample is perfectly homogeneous, and identical spectra are obtained by irradiating different areas. On one hand, the data indicate that this method is highly effective for oligonucleotide MALDI analysis, and on the other, that it can be validly employed for fully automated MALDI procedures. Copyright (C) 2008 John Wiley & Sons, Ltd.
(literal)