http://www.cnr.it/ontology/cnr/individuo/prodotto/ID37124
Accurate analysis of multicomponent fuel spray evaporation in turbulent flow (Articolo in rivista)
- Type
- Label
- Accurate analysis of multicomponent fuel spray evaporation in turbulent flow (Articolo in rivista) (literal)
- Anno
- 2012-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1007/s00348-011-1169-0 (literal)
- Alternative label
Rauch B. 1, Calabria R. 2, Chiariello F. 2, Le Clercq P. 1, Massoli P. 2, Rachner M. 1 (2012)
Accurate analysis of multicomponent fuel spray evaporation in turbulent flow
in Experiments in fluids (Print)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Rauch B. 1, Calabria R. 2, Chiariello F. 2, Le Clercq P. 1, Massoli P. 2, Rachner M. 1 (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1) Institute of Combustion Technology, German Aerospace Center
(DLR), Stuttgart, Germany; 2) Istituto Motori, CNR, Napoli, Italy. (literal)
- Titolo
- Accurate analysis of multicomponent fuel spray evaporation in turbulent flow (literal)
- Abstract
- The aim of this paper is to perform an accurate analysis of the evaporation of single component and binary mixture fuels sprays in a hot weakly turbulent pipe flow by means of experimental measurement and numerical simulation. This gives a deeper insight into the relationship between fuel composition and spray evaporation. The turbulence intensity in the test section is equal to 10%, and the integral length scale is three orders of magnitude larger than the droplet size while the turbulence microscale (Kolmogorov scales) is of same order as the droplet diameter. The spray produced by means of a calibrated droplet generator was injected in a gas flow electrically preheated.
N-nonane, isopropanol, and their mixtures were used in the tests. The generalized scattering imaging technique was applied to simultaneously determine size, velocity, and spatial location of the droplets carried by the turbulent flow in the quartz tube. The spray evaporation was computed
using a Lagrangian particle solver coupled to a gas-phase solver. Computations of spray mean diameter and droplet size distributions at different locations along the pipe compare very favorably with the measurement results. This combined research tool enabled further investigation concerning the influencing parameters upon the evaporation process such as the turbulence, droplet internal mixing, and liquid-phase thermophysical properties. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di