Investigation on the performances of multiple microstrip CdTe detectors (Articolo in rivista)
- Type
- Label
- Investigation on the performances of multiple microstrip CdTe detectors (Articolo in rivista) (literal)
- Anno
- 2007-01-01T00:00:00+01:00 (literal)
- Alternative label
Raulo A, Auricchio N, Cola A, Donati A, Dusi W, Gostilo V, Landini G, Perillo E, Siffert P, Sowinska M, Ventura G (2007)
Investigation on the performances of multiple microstrip CdTe detectors
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Raulo A, Auricchio N, Cola A, Donati A, Dusi W, Gostilo V, Landini G, Perillo E, Siffert P, Sowinska M, Ventura G (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Univ Naples Federico II, Dipartimento Sci Fisiche, I-80126 Naples, Italy;
Ist Nazl Fis Nucl, Sez Naples, I-80126 Naples, Italy;
IASF, INAF, Sez Bologna, I-40139 Bologna, Italy;
Univ Ferrara, Dipartmento Fis, I-44100 Ferrara, Italy;
CNR-IMM, Sez Lecce, I-73100 Lecce, Italy;
Ist Nazl Fis Nucl, Sez Bologna, I-40129 Bologna, Italy;
BSI, LV-1005 Riga, Latvia; EMRS, F-67037 Strasbourg, France;
EURORAD, F-67037 Strasbourg, France (literal)
- Titolo
- Investigation on the performances of multiple microstrip CdTe detectors (literal)
- Abstract
- A study of the spectroscopic response of several large-size CdTe detectors equipped with a conventional cathode and a multimicrostrip anode (15 strips, each 150 mu m wide, 500 mu m pitch) was carried out. Measurements were performed scanning the detector across the strips, by means of a narrow rectangular photon beam (Co-57 and Cd-109 sources), with its longer side oriented parallel to the strip direction, at normal incidence, in order to evaluate the detector behavior when the photon beam impinges at the strip position and at different positions inside the gaps. The detectors were also irradiated changing the value of the angle 0 between the photon beam direction and the normal to the cathode surface in the range 0 degrees < 0 < 70 degrees. The behaviors of the 14, 22, 88 and 122 keV energy peaks have been analyzed. From the scanning along and across the strips some degree of spatial non-uniformity has been observed. As expected, the spectroscopic performance of microstrip detectors is only slightly dependent on the angle, i.e. out strip design is working well. Further measurements are in progress to study the observed charge sharing between adjacent strips, in order to understand if these detectors are suitable to be used as position sensitive devices with spectroscopic capabilities to build up focal planes of X-ray telescopes for astrophysics applications. (literal)