Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles (Articolo in rivista)

Type
Label
  • Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles (Articolo in rivista) (literal)
Anno
  • 2004-01-01T00:00:00+01:00 (literal)
Alternative label
  • Perillo E, Cola A, Donati A, Dusi W, Landini G, Raulo A, Ventura G, Vitulli S (2004)
    Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Perillo E, Cola A, Donati A, Dusi W, Landini G, Raulo A, Ventura G, Vitulli S (literal)
Pagina inizio
  • 125 (literal)
Pagina fine
  • 133 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 531 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Univ Naples Federico II, Dipartimento Sci Fis, UdR INFM, I-80126 Naples, Italy; Sez INFN, Sez Napoli, I-80126 Naples, Italy; CNR, IMM, Sez Lecce, I-73100 Lecce, Italy; CNR, IASF, Sez Bologna, I-40129 Bologna, Italy; Ist Nazl Fis Nucl, Sez Bologna, I-40127 Bologna, Italy (literal)
Titolo
  • Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles (literal)
Abstract
  • A study of the spectroscopic response of a CdTe detector, 10 mm x 3 mm x 3 mm in size, equipped with a 10 mm x 3 mm full cathode and a 10 mm x 0.3 mm central strip anode placed between two parallel focusing strips spaced of about 0.050 mm from the collecting anode, was carried out. This configuration increases the intensity of the weighing field surrounding the anode strip, thus improving the collection of the electrons. The detector was irradiated through the cathode by a narrow photon beam (Co-57 source) at various impinging angles theta in the range 0-87degrees, theta being the angle between the photon beam axis and the normal to the cathode surface, aiming at obtaining better spectroscopic performance. The measurements were carried out with the long side of the beam spot (0.90 mm x 0.18 mm) oriented both transversal and parallel to the central strip anode. In this last case, significant improvements for some spectroscopic parameters were obtained; e.g. the peak-to-valley ratio of the 122-keV peak changes from 13.5 at 0degrees to 25.8 at 82degrees, i.e. an almost two times better value. (literal)