http://www.cnr.it/ontology/cnr/individuo/prodotto/ID35560
Biomimetic sensors for dioxins detection in food samples (Articolo in rivista)
- Type
- Label
- Biomimetic sensors for dioxins detection in food samples (Articolo in rivista) (literal)
- Anno
- 2005-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.snb.2005.03.054 (literal)
- Alternative label
Mascini M., Macagnano A., Scortichini G., Del Carlo M., Diletti G., D'Amico A., Di Natale C., Compagnone D. (2005)
Biomimetic sensors for dioxins detection in food samples
in Sensors and actuators. B, Chemical (Print)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Mascini M., Macagnano A., Scortichini G., Del Carlo M., Diletti G., D'Amico A., Di Natale C., Compagnone D. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Univ Teramo, Dipartimento Sci Alimenti, I-64023 Teramo, Italy; CNR, Sez Roma, IMM, I-00133 Rome, Italy; Ist Zooprofilattico Abruzzo & Molise G Caporale, I-64100 Teramo, Italy; Univ Roma Tor Vergata, Dipartimento Ingn Elettron, I-00133 Rome, Italy; Cranfield Univ, Inst BioSci & Technol, Cranfield MK43 0AL, Beds, Englan (literal)
- Titolo
- Biomimetic sensors for dioxins detection in food samples (literal)
- Abstract
- In this work, gold based quartz crystals were modified with synthetic oligopeptides, designed as biomimetic traps using computational approach, to obtain piezoelectric sensors selective to the dioxins. After the optimisation of the methodology using standard solutions, as a practical analytical application, three food matrices (poultry, eggs and milk) spiked at three different dioxin levels were analysed. The cross-reactivity of the system was also quantified spiking the samples with commercial polychlorinated biphenyls (PCBs) and a mixture of PCBs and dioxins. The response of the sensors was not influenced by any of matrices tested either before or after the cleanup steps. The negligible rnatrix-effect could lead to a simplification of the extraction procedure. Basing on this screening method a rapid assignment of the samples to different degrees of toxicity could be possible reducing the use of high-resolution gas chromatography and high-resolution mass spectrometry (HRGC/HRMS). (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di