Fs/ns Dual-Pulse LIBS Analytic Survey for Copper-Based-Alloys (Articolo in rivista)

Type
Label
  • Fs/ns Dual-Pulse LIBS Analytic Survey for Copper-Based-Alloys (Articolo in rivista) (literal)
Anno
  • 2007-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.apsusc.2007.07.203 (literal)
Alternative label
  • Santagata A.; Teghil R.; Albano G.; Spera D.; Villani P.; De Bonis A.; Parisi G.P.; Galasso A. (2007)
    Fs/ns Dual-Pulse LIBS Analytic Survey for Copper-Based-Alloys
    in Applied surface science; ELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS, AMSTERDAM (Paesi Bassi)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Santagata A.; Teghil R.; Albano G.; Spera D.; Villani P.; De Bonis A.; Parisi G.P.; Galasso A. (literal)
Pagina inizio
  • 863 (literal)
Pagina fine
  • 867 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.sciencedirect.com/science/article/pii/S0169433207011233 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 254 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 4 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR-IMIP, Unità Operativa di Potenza, Zona Industriale di Tito Scalo, 85050 Tito Scalo, PZ, Italy Università degli Studi della Basilicata, Dipartimento di Chimica, Via N. Sauro 85, 85100 Potenza, Italy (literal)
Titolo
  • Fs/ns Dual-Pulse LIBS Analytic Survey for Copper-Based-Alloys (literal)
Abstract
  • The quantitative analytic capability of a fs/ns dual-pulse Laser-Induced Breakdown Spectroscopy technique, based on the orthogonal reheating of a fs-laser ablation plume by a ns-laser pulse, is presented. In this work, it is shown how the effect played by the delay times between the two laser beams can vary the analytical response of this dual-pulse LIBS configuration. In order to address this task, the Sn, Pb and Zn calibration curves of five certified copper-based samples have been investigated. These calibration curves have been obtained, in air at atmospheric pressure, by integrating the emission data collected in two different inter-pulse delay zones, one in the delay interval of 1-41 ms, the other within the range of 46-196 ms. For drawing the species calibration curves, the emission intensities of the considered Pb(I), Sn(I) and Zn(I) electronic transitions have been normalized with a non-resonant Cu(I) emission line. The experimental results have shown that, by varying the inter-pulse delay between the two laser beams, complementary analytical results can be induced. By considering at once all data acquired within the inter-pulse delay time of 1- 196 ms, this hypothesis has been strengthened. The calibration curves obtained in this way are characterized by excellent linear regression coefficients (0.988-0.999) despite of the large Sn, Pb and Zn compositional variation of the targets employed. The results presented reveal, for the first time, that, by taking into account the role played by the inter-pulse delay time between the two laser beams, the fs/ns dual-pulse LIBS configuration here used can be improved and provide very good opportunities for performing quantitative analysis of copper-based alloys. (literal)
Editore
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
Insieme di parole chiave di
data.CNR.it