http://www.cnr.it/ontology/cnr/individuo/prodotto/ID318604
System approach to modeling of liver glucose metabolism with physiologically interpreted model parameters outgoing from [F-18]FDG concentrations measured by PET (Articolo in rivista)
- Type
- Label
- System approach to modeling of liver glucose metabolism with physiologically interpreted model parameters outgoing from [F-18]FDG concentrations measured by PET (Articolo in rivista) (literal)
- Anno
- 2012-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.cmpb.2012.03.005 (literal)
- Alternative label
Rausova, Zuzana; Chrenova, Jana; Nuutila, Pirjo; Iozzo, Patricia; Dedik, Ladislav (2012)
System approach to modeling of liver glucose metabolism with physiologically interpreted model parameters outgoing from [F-18]FDG concentrations measured by PET
in Computer methods and programs in biomedicine (Print)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Rausova, Zuzana; Chrenova, Jana; Nuutila, Pirjo; Iozzo, Patricia; Dedik, Ladislav (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Slovak University of Technology Bratislava; University of Turku; Consiglio Nazionale delle Ricerche (CNR) (literal)
- Titolo
- System approach to modeling of liver glucose metabolism with physiologically interpreted model parameters outgoing from [F-18]FDG concentrations measured by PET (literal)
- Abstract
- New mathematical models from physiologically interpreted parameters capable of evaluating glucose metabolism within the liver and/or the whole body were developed. (literal)
- The group of pigs in a fasting state and the group of pigs with euglycemic supraphysiological hyperinsulinemia were scanned by positron emission tomography after a single dose of [F-18]FDG tracer. Simultaneously frequent sampling of the dynamic data of [F-18]FDG plasma concentration in artery, portal vein and hepatic vein was obtained. A system approach to the liver and/or the whole-body system by the tools of linear dynamic sysztem theory was used. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di