http://www.cnr.it/ontology/cnr/individuo/prodotto/ID315145
LaBr3 scintillator response to admixed neutron and gamma-ray fluxes (Articolo in rivista)
- Type
- Label
- LaBr3 scintillator response to admixed neutron and gamma-ray fluxes (Articolo in rivista) (literal)
- Anno
- 2013-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.nima.2013.05.055 (literal)
- Alternative label
Cazzaniga, C.; Croci, G.; Giacomelli, L.; Grosso, G.; Nocente, M.; Tardocchi, M.; Gorini, G.; Weller, A. (2013)
LaBr3 scintillator response to admixed neutron and gamma-ray fluxes
in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Cazzaniga, C.; Croci, G.; Giacomelli, L.; Grosso, G.; Nocente, M.; Tardocchi, M.; Gorini, G.; Weller, A. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://www.sciencedirect.com/science/article/pii/S016890021300661X (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- [ 1 ] Univ Milano Bicocca, Milan, Italy;
[ 2 ] CNR, Ist Fis Plasma Piero Caldirola, I-20133 Milan, Italy;
[ 3 ] IPP EuratomAssoc, Max Planck Inst Plasmaphys, Garching, Germany (literal)
- Titolo
- LaBr3 scintillator response to admixed neutron and gamma-ray fluxes (literal)
- Abstract
- The gamma-ray spectroscopy is a promising method for diagnosing fast ions and confined,m particles in a fusion plasma device. This application requires gamma-ray detectors with high energy resolution (say a few percent for gamma-ray energies in the range 1-5 MeV), high efficiency and high count rate capability, ideally up to a few Ml-lz. Furthermore, the detector will have to withstand the high 14 MeV and 2.45 MeV neutron fluxes produced by the main fusion reactions between deuterium and tritium. Experimental results demonstrate that the requirements on energy resolution, efficiency and count rate can be met with a LaBr3(Ce) scintillator detector equipped with fast digital data acquisition. The measured response of the detector to 2.45 MeV neutrons is presented in this paper and discussed in terms of the interaction mechanism between neutrons and detector. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di