Monitoring the air quality around an oil refinery through the use of diffusive sampling (Articolo in rivista)

Type
Label
  • Monitoring the air quality around an oil refinery through the use of diffusive sampling (Articolo in rivista) (literal)
Anno
  • 2004-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1007/s00216-003-2389-9 (literal)
Alternative label
  • De Santis, F., Fino, A., Menichelli, S., Vazzana, C., Allegrini, I. (2004)
    Monitoring the air quality around an oil refinery through the use of diffusive sampling
    in Analytical & bioanalytical chemistry (Print); Springer Heidelberg, Heidelberg (Germania)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • De Santis, F., Fino, A., Menichelli, S., Vazzana, C., Allegrini, I. (literal)
Pagina inizio
  • 782 (literal)
Pagina fine
  • 788 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 378 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 7 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR-IIA,Istituto Inquinamento Atmosferico, CP 10, Monterotondo Scalo, 00016 Roma, Italy (literal)
Titolo
  • Monitoring the air quality around an oil refinery through the use of diffusive sampling (literal)
Abstract
  • Diffusive sampling has been used to study the spatial distribution of SO2, NO2, NOx, NH3, and BTX (benzene, toluene and xylenes nera an oil refinery located in Falconara, Italy, over the period from March to October 2001. Three different categories of sampling sites (road-side, residential and background) were studied. In total, 56 sites were monitored.There results were evaluated on the basis of the limit values found in the European Directives. The results of the defined study indicate that the measured concentrations were substantially lower than the ambient air quality standard with the maximum concentrations beng generally found much closer to emission sources. The monitoring method described here can be used to assess integrated concentration levels over long periods of time and to identify pollution \"hotspots\" where concentrations are likely to be consistently high. Identificantion of these hotspots may help to assess air quality and to implement proper action plans, especially in locations where industrial and urban pollution coexist. (literal)