A Low Frequency Electromagnetic Sensor for Indirect Measurement of Glucose Concentration: In Vitro Experiments in Different Conductive Solutions (Articolo in rivista)

Type
Label
  • A Low Frequency Electromagnetic Sensor for Indirect Measurement of Glucose Concentration: In Vitro Experiments in Different Conductive Solutions (Articolo in rivista) (literal)
Anno
  • 2010-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.3390/s100605346 (literal)
Alternative label
  • Tura A; Sbrignadello S; Cianciavicchia D; Pacini G; Ravazzani P (2010)
    A Low Frequency Electromagnetic Sensor for Indirect Measurement of Glucose Concentration: In Vitro Experiments in Different Conductive Solutions
    in Sensors (Basel)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Tura A; Sbrignadello S; Cianciavicchia D; Pacini G; Ravazzani P (literal)
Pagina inizio
  • 5346 (literal)
Pagina fine
  • 5358 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 10 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 6 (literal)
Note
  • Scopu (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Tura A, Sbrignadello S, Pacini G: Istituto di Ingegneria Biomedica ISIB-CNR, Padua, Italy; Ravazzani P: Istituto di Ingegneria Biomedica ISIB-CNR, Milano, Italy; Cianciavicchia D: Bellco S.r.l., Via Camurana 1, 41037, Mirandola (MO), Italy (literal)
Titolo
  • A Low Frequency Electromagnetic Sensor for Indirect Measurement of Glucose Concentration: In Vitro Experiments in Different Conductive Solutions (literal)
Abstract
  • In recent years there has been considerable interest in the study of glucose-induced dielectric property variations of human tissues as a possible approach for non-invasive glycaemia monitoring. We have developed an electromagnetic sensor, and we tested in vitro its ability to estimate variations in glucose concentration of different solutions with similarities to blood (sodium chloride and Ringer-lactate solutions), differing though in the lack of any cellular components. The sensor was able to detect the effect of glucose variations over a wide range of concentrations (similar to 78-5,000 mg/dL), with a sensitivity of similar to 0.22 mV/(mg/dL). Our proposed system may thus be useful in a new approach for non-invasive and non-contact glucose monitoring. (literal)
Prodotto di
Autore CNR

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi