An instrument for prosthesis osseointegration assessment by electrochemical impedance spectrum measurement (Articolo in rivista)

Type
Label
  • An instrument for prosthesis osseointegration assessment by electrochemical impedance spectrum measurement (Articolo in rivista) (literal)
Anno
  • 2008-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.measurement.2008.02.008 (literal)
Alternative label
  • Arpaia, P; Clemente, F; Romanucci, C (2008)
    An instrument for prosthesis osseointegration assessment by electrochemical impedance spectrum measurement
    in Measurement (Lond., Print)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Arpaia, P; Clemente, F; Romanucci, C (literal)
Pagina inizio
  • 1040 (literal)
Pagina fine
  • 1044 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 41 (literal)
Rivista
Note
  • Scopu (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1: Dipartimento di Ingegneria, Universita` del Sannio, Corso Garibaldi 107, 82100 Benevento, Italy / 2, 3: Consiglio Nazionale delle Ricerche, Istituto di Ingegneria Biomedica, Via Salaria km 29,300, 00016 Monterotondo S. (RM), Italy (literal)
Titolo
  • An instrument for prosthesis osseointegration assessment by electrochemical impedance spectrum measurement (literal)
Abstract
  • A method based on electrochemical impedance spectroscopy (EIS) for the diagnosis of prosthesis osseointegration was proposed by the authors in previous works [P. Arpaia, F. Clemente, A. Zanesco, Low-invasive diagnosis of metallic prosthesis osseointegration by electrical impedance spectroscopy, IEEE Trans. Instrum. Meas. 56 (3) (2007) 784-789; P. Arpaia, F. Clemente, C. Romanucci, Impedance spectroscopy-based measurement of cochlear prosthesis osseointegration: in vivo test procedure and characterization, in: Proceedings of IMTC 2007, Warsaw (Poland), pp. 1786-1791]. In this paper, the design, the implementation, and the metrological characterization of a microcontroller-based prototype conceived as a stand alone instrument to be used for in vivo clinical applications are presented. Particulars on the preliminary experimental results of laboratory evaluation are presented. (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it