High Resolution Imaging System (HiRIS) based on H9500 PSPMT (Articolo in rivista)

Type
Label
  • High Resolution Imaging System (HiRIS) based on H9500 PSPMT (Articolo in rivista) (literal)
Anno
  • 2008-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.nima.2008.05.052 (literal)
Alternative label
  • Trotta C.; Massari R.; Trinci G.; Palermo N.; Boccalini S.; Scopinaro F.; Soluri, A (2008)
    High Resolution Imaging System (HiRIS) based on H9500 PSPMT
    in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT; ELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS, AMSTERDAM (Paesi Bassi)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Trotta C.; Massari R.; Trinci G.; Palermo N.; Boccalini S.; Scopinaro F.; Soluri, A (literal)
Pagina inizio
  • 454 (literal)
Pagina fine
  • 458 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://puma.isti.cnr.it/linkres.php?resource=cnr.isib/cnr.isib/2008-A0-007 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 593 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 3 (literal)
Note
  • Scopu (literal)
  • ISI Web of Science (WOS) (literal)
  • PuM (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Trotta, Massari, Soluri: Institute of Biomedical Engineering, CNR, Rome, Italy and Li-tech SpA, Monterotondo (RM), Italy / Trinci, Boccalini: Institute of Biomedical Engineering, CNR, Rome, Italy / Palermo: Li-tech SpA, Monterotondo (RM), Italy and Microtelecom SRL, Lauzacco Pavia di Udine (UD), Italy / Scopinaro: Institute of Biomedical Engineering, CNR, Rome, Italy and Department of Radiological Sciences, University ''La Sapienza'' Rome, Italy (literal)
Titolo
  • High Resolution Imaging System (HiRIS) based on H9500 PSPMT (literal)
Abstract
  • The H8500 PhotoMultiplier Tube (PMT) from Hamamatsu has been used in the last years to assemble several scintigraphic devices in order to achieve high-resolution gamma cameras. If the detector is coupled to discrete scintillator with millimetric pixel size, the resulting charge distribution that emerges is not properly sampled by its anodes (6×6 mm2). The new position sensitive PMT H9500, with its 3×3 mm2 anodes, allows a better charge distribution sampling, improving both spatial resolution and linearity of the system. In this paper, we investigate the imaging performances of the H9500 PMT coupled with a CsI(Tl) array having 1 mm pixel size and compare the results with the same scintillator coupled with H8500 PMT. A portable imaging system named HiRIS (High-Resolution Imaging System) was then realized using a miniaturized readout electronic. Thanks to its lightness, it can be easily used in Medical Imaging. We used HiRIS, together with a rotating system, to carry out a tomographic reconstruction of the biodistribution of a radiopharmaceutical in rats. (literal)