http://www.cnr.it/ontology/cnr/individuo/prodotto/ID30131
One Inch Field of view imaging probe for breast cancer sentinel node location (Articolo in rivista)
- Type
- Label
- One Inch Field of view imaging probe for breast cancer sentinel node location (Articolo in rivista) (literal)
- Anno
- 2003-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/S0168-9002(02)01898-3 (literal)
- Alternative label
D'Errico, G.; Scafé, R.;Soluri, A.;Schiaratura, A.; Mangano, A. M.;David, V.;Scopinaro, F. (2003)
One Inch Field of view imaging probe for breast cancer sentinel node location
in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT; ELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS, AMSTERDAM (Paesi Bassi)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- D'Errico, G.; Scafé, R.;Soluri, A.;Schiaratura, A.; Mangano, A. M.;David, V.;Scopinaro, F. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://biblioproxy.cnr.it:2050/science/article/pii/S0168900202018983 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1-Policlinico Agostino Gemelli, Roma, Italy
2-Centro Ricerche Casaccia, Enea, Italy
3-ITBM, CNR, Italy
4 Capodarco Elettronica Paliano (FR), Italy
5-6-7 Policlinico Umberto I, Roma, Italy (literal)
- Titolo
- One Inch Field of view imaging probe for breast cancer sentinel node location (literal)
- Abstract
- The already reported 1-in.2 field of view mini gamma camera known since 1998 with the name of Imaging Probe (IP), has been used for sentinel node localization by a medical equipe that, though trained by the group of nuclear physicians of the University \"La Sapienza\" who first conceived and used this detector, has used IP in its own Hospital to: (1) gain experience for future use during operations--a cooperative work on IP radio guided orthopaedic operations has already started working, and (2) to start with IP multicenter trials.
In six patients with breast cancer, who underwent lymphoscintigraphy for sentinel node biopsy, sentinel node was checked and located with IP and non-imaging Neoprobe 2000 CdTe (Zn) probe, independent of location by means of large field of view Anger camera. Operators who used Neoprobe and IP were blinded to each other and not aware of the results of Anger camera imaging. Anger camera, as well as IP and neoprobe detected 7 nodes in 6 pts. Detection time was 2?, 06? SD 26? with IP and 2?, 18? SD 47? with neoprobe 2000. The most difficult to find node required 2 min and 56 s--inside sd--for IP detection and 3 min and 45 s with neoprobe. Subjective impression of being sure of having detected sentinel node was: absolutely sure on 7/7 nodes with IP and on 5/7 nodes with neoprobe. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di