Results of clinical trials with SPEM (Articolo in rivista)

Type
Label
  • Results of clinical trials with SPEM (Articolo in rivista) (literal)
Anno
  • 2003-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/S0168-9002(02)01891-0 (literal)
Alternative label
  • De Vincentis, G.; Scopinaro, F.; Pani, R.;Pellegrini, R.;Soluri, A.; Scafè, R.;Massa, R.;Cinti, M .N.;Weimberg, I. N.; Khalkhali, I.;Betti, M. (2003)
    Results of clinical trials with SPEM
    in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT; ELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS, AMSTERDAM (Paesi Bassi)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • De Vincentis, G.; Scopinaro, F.; Pani, R.;Pellegrini, R.;Soluri, A.; Scafè, R.;Massa, R.;Cinti, M .N.;Weimberg, I. N.; Khalkhali, I.;Betti, M. (literal)
Pagina inizio
  • 46 (literal)
Pagina fine
  • 50 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://biblioproxy.cnr.it:2050/science/article/pii/S0168900202018910 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 497 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 1 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1-2-3-4-7-8-11 Department of Experimental Medicine and Pathology, Section of Nuclear Medicine c/o Ist. Radiologia Centrale Università of Rome, \"La Sapienza\", Viale Regina Elena 324, 00161 Rome, Italy 5 National Research Council - ITBM, Pile A. Moro 7, Rome, Italy 6 ENEA-TEC, CR Casaccia Rome, Italy 9 PEM Technologies Inc., 5611 Roosevelt Dr., Bethesda, MA, USA 10 Harbor UCLA Medical Center, Torrance, CA, USA (literal)
Titolo
  • Results of clinical trials with SPEM (literal)
Abstract
  • X-ray mammography represents the principal tool for breast cancer screening, but has several limitations. Due to the low specificity of X-ray mammography, many more biopsies are performed than are necessary. More than 60% of breast biopsies performed because of suspicious X-ray mammograms yield a diagnosis other than cancer. In women with X-ray dense breast tissue, X-ray mammography can miss as many as 20% of cancers. Several studies suggest that combining 99mTc Sestamibi Scintimammography (SM) with X-ray mammography can increase the accuracy of breast imaging in selected populations. The principal limitation of prone-position scintimammography (PSM) using a standard Anger gamma camera is low sensitivity for subcentimeter cancers (i.e., stages T1a and T1b). Detecting these small cancers is extremely important clinically, since removal of the cancers at these early stages is thought to represent the best opportunity for cure. Our group constructed a high spatial resolution detector specifically dedicated to SM, the Single Photon Emission Mammography (SPEM) camera. Unlike conventional Anger gamma cameras, the SPEM camera incorporates a high spatial resolution position-sensitive photomultiplier tube, coupled to an array of scintillating crystals. The compactness of the SPEM camera allows breast compression to be implemented in a cranio-caudal view, facilitating comparison to X-ray mammograms taken in the same position. Clinical results so obtained have demonstrated increased diagnostic sensitivity in sub-centimeter tumors (80% for SPEM vs 50% with PSM). Factors contributing to this increased sensitivity include improved signal-to-noise ratio (SNR). For sub-centimeter cancers, SPEM SNR values were consistently much higher than those of PSM. Classic detectability studies have demonstrated that an SNR value >5 is required for reliable detection of cancers. For subcentimeter cancers, only the SPEM attained or exceeded this minimum threshold. The results showed that compression, which optimizes resolution by reducing lesion-to-collimator distance, and increases planar image contrast by reducing signal and attenuation from interposed normal breast tissue, plays a fundamental role in the visualization of subcentimeter breast cancers. (literal)
Editore
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
Insieme di parole chiave di
data.CNR.it