http://www.cnr.it/ontology/cnr/individuo/prodotto/ID286751
Reverse Current for the Prevention of Anodic Oxidation during exposure to Air - \"ICCP Test Report\" (Rapporti progetti di ricerca)
- Type
- Label
- Reverse Current for the Prevention of Anodic Oxidation during exposure to Air - \"ICCP Test Report\" (Rapporti progetti di ricerca) (literal)
- Anno
- 2014-01-01T00:00:00+01:00 (literal)
- Alternative label
L. Di Giovanni, G. Brunaccini, M. Ferraro, V. Antonucci (2014)
Reverse Current for the Prevention of Anodic Oxidation during exposure to Air - "ICCP Test Report"
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- L. Di Giovanni, G. Brunaccini, M. Ferraro, V. Antonucci (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- https://www.itae.cnr.it (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- L. Di Giovanni, G. Brunaccini, M. Ferraro, V. Antonucci (literal)
- Titolo
- Reverse Current for the Prevention of Anodic Oxidation during exposure to Air - \"ICCP Test Report\" (literal)
- Abstract
- This report intends to describe the experimental activity done and the results achieved at CNR, during the test for SOFC anode protection by means of ICCP method in a short stack.
The work include stack commissioning (performance verification) and anode protection test (ICCP test).
The activies were carried out in twice.
In both iterations, the tests analysed 48 cm2 active area (single cell) planar stacks whose power was about 120 W.
The two stacks differed from the number of cells.
The former stacks consisted of 6 cells, the latter consisted of 7 cells. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Insieme di parole chiave di