http://www.cnr.it/ontology/cnr/individuo/prodotto/ID280179
QUANTITATIVE ON-LINE ANALYSIS OF FLAME-FORMED PAH BY MOLECULAR BEAM TIME OF FLIGHT MASS SPECTROMETRY (MB-TOFMS) (Abstract/Poster in atti di convegno)
- Type
- Label
- QUANTITATIVE ON-LINE ANALYSIS OF FLAME-FORMED PAH BY MOLECULAR BEAM TIME OF FLIGHT MASS SPECTROMETRY (MB-TOFMS) (Abstract/Poster in atti di convegno) (literal)
- Anno
- 2014-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.4405/profic2014.C27 (literal)
- Alternative label
M. Passaro 1, V. Gargiulo 2, A. Tregrossi 2, X. Wang 3, N. Spinelli 4, B. Apicella 2 (2014)
QUANTITATIVE ON-LINE ANALYSIS OF FLAME-FORMED PAH BY MOLECULAR BEAM TIME OF FLIGHT MASS SPECTROMETRY (MB-TOFMS)
in Joint Meeting: French and Italian Sections - IFRF and The Combustion Institute, Pisa, 23-24 Aprile 2014
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- M. Passaro 1, V. Gargiulo 2, A. Tregrossi 2, X. Wang 3, N. Spinelli 4, B. Apicella 2 (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
- Joint Meeting: French and Italian Sections - IFRF and The Combustion Institute - Abstract Book (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1 CNISM and DICMAPI, Università degli Studi di Napoli Federico II, P.le Tecchio, 80, Napoli, Italy
2 Istituto di Ricerche sulla Combustione (IRC-CNR), P.le Tecchio 80, Napoli, Italy
3 SPIN-C.N.R., Via Cinthia, 26, Napoli, Italy
4 CNISM and DSF, Università degli Studi di Napoli Federico II, Via Cinthia, 26, Napoli, Italy (literal)
- Titolo
- QUANTITATIVE ON-LINE ANALYSIS OF FLAME-FORMED PAH BY MOLECULAR BEAM TIME OF FLIGHT MASS SPECTROMETRY (MB-TOFMS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
- 978-88-88104-16-4 (literal)
- Abstract
- Polycyclic aromatic hydrocarbons (PAH), formed from incomplete combustion of a wide
range of combustion sources, are believed to be hazardous to human health and to be soot
precursors.
The current European legislation provides PAH monitoring from exhaust through timeconsuming
sampling by condensation, washing by solvent, filtration and off-line mass
spectrometric analysis. Continuous on-line measurement of PAH inside and at the exhaust
of combustion systems is still challenging. This is due to the small concentrations and
limited selectivity of available measurement methods.
The development of on-line mass spectrometric analysis, such as flame-sampling
Molecular-Beam Time of Flight Mass Spectrometry (MB-TOFMS), has enabled the
selective and sensitive detection of PAH, since the expansion of the flame gases through a
nozzle into a lower pressure region leads to the formation of a nearly collisionless
molecular beam. In the past several years, substantial progress has been achieved by
supplementing traditional electron ionization molecular-beam mass spectrometry (EI-MBMS)
with isomer-specific measurements using photo-ionization (PI-MBMS). However the
inherent characteristics of on-line sampling and laser ionization allow PAH identification
and comparative profiles along the flame evaluation whereas prevent PAH quantitative
determination.
In this work a quantitative analysis of flame-formed PAH with a MB-TOFMS is proposed
through a calibration made with off-line techniques.
Flame products from a premixed atmospheric pressure ethylene/oxygen laminar flame just
above the soot formation threshold have been collected for several hours and concurrently
analyzed on-line with the MB-TOFMS apparatus. The collected samples were extracted in
solvent and off-line analysed by conventional GC-MS for quantitative determination of
PAH. The GC-MS undetectable fraction was moreover analysed by other off-line chemical
and spectroscopic techniques. From the on-line mass spectra acquired, the total area of each
flame species has been evaluated and related to its concentration obtained by means of GCMS,
thus calibrating the MB-TOFMS apparatus. Moreover, a measure of the sensitivity of
such experimental apparatus and a comparison with the common off-line, less sensitive and
more time-expensive, GC-MS for PAH analysis is given. (literal)
- Prodotto di
- Autore CNR
Incoming links:
- Autore CNR di
- Prodotto