http://www.cnr.it/ontology/cnr/individuo/prodotto/ID27639
Mixing and matching in ceramic-on-metal hip arthroplasty: an in-vitro hip simulator study . (Articolo in rivista)
- Type
- Label
- Mixing and matching in ceramic-on-metal hip arthroplasty: an in-vitro hip simulator study . (Articolo in rivista) (literal)
- Anno
- 2009-01-01T00:00:00+01:00 (literal)
- Alternative label
Affatato S, Spinelli M, Squarzoni S, Traina F, Toni A. (2009)
Mixing and matching in ceramic-on-metal hip arthroplasty: an in-vitro hip simulator study .
in Journal of Biochemistry (Tokyo)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Affatato S, Spinelli M, Squarzoni S, Traina F, Toni A. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy; IGM-CNR, Unit of Bologna c/o IOR, Bologna, Italy ; Dipartimento di Ortopedia Traumatologia, Istituto Ortopedico Rizzoli, Bologna, Italy (literal)
- Titolo
- Mixing and matching in ceramic-on-metal hip arthroplasty: an in-vitro hip simulator study . (literal)
- Abstract
- The clinical success of second-generation metal-on-metal hip replacement and the good tribological performance of alumina ceramic revived an interest in hip articulation as a solution to reduce wear. This study was aimed at characterizing the wear behaviour of new hybrid ceramic-on-metal bearings. In particular, this study investigated the wear behaviour of ceramic-on-metal hip components (three different diameters configurations: 28, 32 and 36 mm), not specifically proposed to be coupled, in order to compare them with ceramic-on-ceramic, which is considered to be the gold standard for wear resistance. For this purpose, the weight loss over a standard wear simulation was monitored. Moreover, scanning electronic microscope observations were used to verify if any carbides removal, for the metallic components, triggered wears debris production promoting abrasive third-body wear. After five million cycles, our results showed significantly greater wear-in ceramic-on-metal compared with ceramic-on-ceramic, and significant greater wear for the 32-mm diameter compared with the 36-mm one. Our findings showed an increase in wear for the proposed hybrid specimens with respect to that of the ceramic-on-ceramic ones confirming that even in the case of ceramic-on-metal bearings, mixing and matching could not prove effective wear behaviour, not even comparable with that of the ceramic-on-ceramic gold standard. Wear patterns and roundness tolerances certainly discourage the coupling of components not specifically intended to be coupled. Unsuitable geometrical conformity could, in fact, result in a poor dynamic behaviour and lead to clinical failure. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di