http://www.cnr.it/ontology/cnr/individuo/prodotto/ID273200
SURFACE ACOUSTIC WAVE BIOSENSOR BASED ON ODORANT BINDING PROTEINS DEPOSITED BY LASER INDUCED FORWARD TRANSFER (Contributo in atti di convegno)
- Type
- Label
- SURFACE ACOUSTIC WAVE BIOSENSOR BASED ON ODORANT BINDING PROTEINS DEPOSITED BY LASER INDUCED FORWARD TRANSFER (Contributo in atti di convegno) (literal)
- Anno
- 2013-01-01T00:00:00+01:00 (literal)
- Alternative label
DI PIETROANTONIO F., CANNATA' D., BENETTI M., VERONA E., DINCA V., DINESCU M., VARRIALE A., D'AURIA S., PALLA-PAPAVLU A., SERA P. (2013)
SURFACE ACOUSTIC WAVE BIOSENSOR BASED ON ODORANT BINDING PROTEINS DEPOSITED BY LASER INDUCED FORWARD TRANSFER
in SURFACE ACOUSTIC WAVE BIOSENSOR BASED ON ODORANT BINDING PROTEINS DEPOSITED BY LASER INDUCED FORWARD TRANSFER, JULY 21-25, 2013
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- DI PIETROANTONIO F., CANNATA' D., BENETTI M., VERONA E., DINCA V., DINESCU M., VARRIALE A., D'AURIA S., PALLA-PAPAVLU A., SERA P. (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- THE IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM PRAGUE, CZECH REPUBLIC (literal)
- Titolo
- SURFACE ACOUSTIC WAVE BIOSENSOR BASED ON ODORANT BINDING PROTEINS DEPOSITED BY LASER INDUCED FORWARD TRANSFER (literal)
- Abstract
- In this study it is presented the development of surface acoustic wave (SAW) biosensors for odor detection in the food industry. The SAW biosensors are coated by laser-induced forward transfer (LIFT) with wild-type bovine odorant binding protein (wtbOBP) solutions containing 20% and 50% glycerol. Optical microscopy investigations revealed that individual droplets could be printed from 50% glycerol solutions with a high resolution. Further investigations proved that despite the lower resolution of the 20% glycerol printed droplets it is possible to achieve higher uniformity in the coverage of the entire active area of the SAW biosensors. In addition, it is shown that the surface density of the wtbOBP LIFT-ed layer is four times higher than in the case of pipette deposition. Finally, the functionality of the SAW biosensors was investigated by testing the biosensors upon exposure to various concentrations of octenol vapors. A high sensitivity, i.e. of 5 Hz/ppm and detection limit in the low ppm range was obtained, lower that what has previously been reported with conventional methods. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Insieme di parole chiave di