http://www.cnr.it/ontology/cnr/individuo/prodotto/ID263830
Mid-infrared quantitative spectroscopy by comb-referencing of a quantum-cascade-laser: Application to the CO2 spectrum at 4.3 mu m (Articolo in rivista)
- Type
- Label
- Mid-infrared quantitative spectroscopy by comb-referencing of a quantum-cascade-laser: Application to the CO2 spectrum at 4.3 mu m (Articolo in rivista) (literal)
- Anno
- 2011-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1063/1.3671081 (literal)
- Alternative label
Gambetta, A. and Gatti, D. and Castrillo, A. and Galzerano, G. and Laporta, P. and Gianfrani, L. and Marangoni, M. (2011)
Mid-infrared quantitative spectroscopy by comb-referencing of a quantum-cascade-laser: Application to the CO2 spectrum at 4.3 mu m
in Applied physics letters
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Gambetta, A. and Gatti, D. and Castrillo, A. and Galzerano, G. and Laporta, P. and Gianfrani, L. and Marangoni, M. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Gambetta, A (Reprint Author), Politecn Milan, Dipartimento Fis, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy. Gambetta, A.; Gatti, D.; Laporta, P.; Marangoni, M., Politecn Milan, Dipartimento Fis, I-20133 Milan, Italy. Castrillo, A.; Gianfrani, L., Univ Naples Federico 2, Dipartimento Sci Ambientali, I-81100 Caserta, Italy. Galzerano, G., CNR, Ist Foton & Nanotecnol, I-20133 Milan, Italy. (literal)
- Titolo
- Mid-infrared quantitative spectroscopy by comb-referencing of a quantum-cascade-laser: Application to the CO2 spectrum at 4.3 mu m (literal)
- Abstract
- A robust phase-lock of a quantum-cascade-laser to a near-infrared frequency-comb allows absorption spectra of a CO2 gas sample to be acquired at different pressures with extreme repeatability and accuracy by tuning the repetition-rate of the comb, thus ensuring an absolute frequency scale on the acquired spectra. The method proves useful to retrieve traceable spectroscopic parameters such as line-center frequencies, line intensity factors, pressure shift, and pressure broadening coefficients, with unprecedented quality from the metrological point of view. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3671081] (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di