Edge thomson scattering on RFX-mod (Articolo in rivista)

Type
Label
  • Edge thomson scattering on RFX-mod (Articolo in rivista) (literal)
Anno
  • 2006-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.2217926 (literal)
Alternative label
  • A. Alfier; R. Pasqualotto (2006)
    Edge thomson scattering on RFX-mod
    in Review of scientific instruments; American Institute Of Physics (AIP), Melville (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • A. Alfier; R. Pasqualotto (literal)
Pagina inizio
  • 10E501 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 77 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
  • Article Number 10E501, Issue 10 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 4 (literal)
Note
  • Scopu (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Dipartimento di Fisica G. Galilei, Università degli Studi di Padova, Via Marzolo 8, I-35100 Padova, Italy - Consorzio RFX-Associazione Euratom-Enea sulla Fusione, corso Stati Uniti 4, I-35127 Padova, Italy; Consorzio RFX-Associazione Euratom-Enea sulla Fusione, corso Stati Uniti 4, I-35127 Padova, Italy (literal)
Titolo
  • Edge thomson scattering on RFX-mod (literal)
Abstract
  • Electron temperature and density profiles of the RFX-mod experiment are characterized by edge gradients typically steeper than the flatter central region. The main Thomson scattering (TS) diagnostic which measures 84-point profiles along a diameter is mainly devoted to cover the core region. A second TS system has been developed to measure 12-point profiles in the external region 0.8 < r/a < 1, with a spatial resolution of 1 cm. It uses a single shot ruby laser. Input and collection optics share the same vacuum port and they are mounted on one optical bench, which allows offline aligning the system before connecting it to the vessel. The scattered signal is collected by a row of 12 fibers, while 4 fibers on the sides are used to check the alignment and measure the plasma light. The fibers, arranged in a 4 x 4 pattern, are fed into a four channel filter spectrometer and the spectrum is detected by a GaAs intensified charge-coupled device camera. The filters are arranged in a zigzag geometry, such that only one detector is needed. (c) 2006 American Institute of Physics. (literal)