Thomson scattering calibration with ultra-bright supercontinuum light source (Articolo in rivista)

Type
Label
  • Thomson scattering calibration with ultra-bright supercontinuum light source (Articolo in rivista) (literal)
Anno
  • 2006-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.2217927 (literal)
Alternative label
  • R. Pasqualotto; A. Alfier (2006)
    Thomson scattering calibration with ultra-bright supercontinuum light source
    in Review of scientific instruments; American Institute Of Physics (AIP), Melville (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • R. Pasqualotto; A. Alfier (literal)
Pagina inizio
  • 10E502 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 77 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
  • Article Number 10E502, Issue 10 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 4 (literal)
Note
  • Scopu (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Consorzio RFX,Associazione Euratom-Enea sulla Fusione, corso Stati Uniti 4, I-35127 Padova, Italy; Dipartimento di Fisica G. Galilei, Università degli Studi di Padova, Via Marzolo 8, I-35100 Padova, Italy - Consorzio RFX,Associazione Euratom-Enea sulla Fusione, corso Stati Uniti 4, I-35127 Padova, Italy (literal)
Titolo
  • Thomson scattering calibration with ultra-bright supercontinuum light source (literal)
Abstract
  • The recently developed supercontinuum light source (SLS) finds a useful application in the calibration of a Thomson scattering (TS) diagnostic. When filter polychromators are used, the relative responsivity of the spectral channels is generally measured with a cw halogen light source from the dc output of the detectors, while the TS signal is measured from an ac output. In a TS system with optical delay lines, like in RFX-mod, a cw light source cannot discriminate differences between the relative responsivities of the positions that share the same polychromator but are connected to different delay lines: this can be achieved with a pulsed white light source instead. In addition a pulsed source with a time response similar to the TS signals would avoid any frequency response problem, because the same ac output of the detectors used for the TS signals could also be used for the calibration. An SLS produces a 5 ns Gaussian pulse, with a wide and smooth spectrum that covers the range of 550-1600 nm. The SLS provides a light source sufficiently bright to calibrate simultaneously all spectrometers. The experimental setup used for the calibration and obtained results are presented. (c) 2006 American Institute of Physics. (literal)