Characterisation of phase evolution under load by means of phase contrast imaging using synchrotron radiation (Articolo in rivista)

Type
Label
  • Characterisation of phase evolution under load by means of phase contrast imaging using synchrotron radiation (Articolo in rivista) (literal)
Anno
  • 2004-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.msea.2004.01.054 (literal)
Alternative label
  • Besseghini, S (1); Stortiero, F (1) ; Carcano, G (1) ; Villa, E (1) ; Mancini, L (2) ; Tromba, G (2) ; Zanini, F (2) ; Montanari, F (2) ; Airoldi, G (3) (2004)
    Characterisation of phase evolution under load by means of phase contrast imaging using synchrotron radiation
    in Materials science & engineering. A, Structural materials: properties, microstructure and processing; ELSEVIER SCIENCE, Losanna (Svizzera)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Besseghini, S (1); Stortiero, F (1) ; Carcano, G (1) ; Villa, E (1) ; Mancini, L (2) ; Tromba, G (2) ; Zanini, F (2) ; Montanari, F (2) ; Airoldi, G (3) (literal)
Pagina inizio
  • 125 (literal)
Pagina fine
  • 129 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 378 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 1-2 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • [ 1 ] CNR, IENI, Unita Lecco, I-23900 Lecco, Italy [ 2 ] Sincrotrone Trieste SCPA, SYRMEP Grp, I-34012 Trieste, Italy [3 ] Univ Milan, Bicocca 53, Dipartimento Sci Mat Cozzi, I-20100 Milan, Italy (literal)
Titolo
  • Characterisation of phase evolution under load by means of phase contrast imaging using synchrotron radiation (literal)
Abstract
  • Phase contrast radiography (PCR) is a quite novel technique that is collecting increasing attention due to the possibility to obtain image information in presence of very small differences in the densities of the materials under analysis. Phase contrast imaging (PCI) has some specific advantage when compared with common microscopic techniques: (a) no special preparation of the sample is needed (b) the simultaneously investigated area is very large and (c) it allows the setting up of complex experimental apparatus. The results here presented are a good evidence of these three advantages. (literal)
Editore
Prodotto di
Autore CNR

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
data.CNR.it