http://www.cnr.it/ontology/cnr/individuo/prodotto/ID253239
Measuring tree and vine ET with eddy covariance (Articolo in rivista)
- Type
- Label
- Measuring tree and vine ET with eddy covariance (Articolo in rivista) (literal)
- Anno
- 2000-01-01T00:00:00+01:00 (literal)
- Alternative label
Snyder R.L., Paw U K.T., Duce P., Spano D., Ferreira, M.I., do Paco T.A., Connell JH (2000)
Measuring tree and vine ET with eddy covariance
in Acta horticulturae; International Society for Horticultural Science (ISHS), Leuven (Belgio)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Snyder R.L., Paw U K.T., Duce P., Spano D., Ferreira, M.I., do Paco T.A., Connell JH (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- Lavoro presentato al 3rd International Symposium on Irrigation of Horticultural Crops, tenuto a ESTORIL, PORTUGAL nel periodo 28 Giugno - 2 Luglio 1999 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://www.actahort.org/books/537/537_3.htm (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- University of California, CNR-IMAes, University of Sassari, University of Lisbon (literal)
- Titolo
- Measuring tree and vine ET with eddy covariance (literal)
- Abstract
- The eddy covariance method is a viable method to measure evapotranspiration from tree and vine crops. However, one must be careful to measure properly the energy balance components and to apply corrections to the heat flux data to obtain good results. Based on several years of experience with energy balance measurements, we have found that failure to achieve the energy closure is often attributable to inaccurate soil heat flux density data. In addition, interference by wind blowing past the mounting tower can lead to spurious results. Although the benefit was small in our experiments, applying the corrections for air temperature and density changes (WPL) are recommended to eliminate errors in sensible and latent heat flux density. This is especially true for high elevations and for locations with extreme temperatures. We found that locating the net radiometer and the eddy covariance instruments above or between the rows seems to have little influence on the measurement as long as the sensors are not too close to the canopy elements indicating that the 'footprints' were not an important factor. In this paper, these aspects of measuring ET with the eddy covariance method and some results will be discussed. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Editore di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di