http://www.cnr.it/ontology/cnr/individuo/prodotto/ID246836
Improved performance of the Thomson scattering system in RFX (Articolo in rivista)
- Type
- Label
- Improved performance of the Thomson scattering system in RFX (Articolo in rivista) (literal)
- Anno
- 1999-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1063/1.1149629 (literal)
- Alternative label
Pasqualotto R.; Sardella A.; Intravaia A.; Marrelli L. (1999)
Improved performance of the Thomson scattering system in RFX
in Review of scientific instruments; AIP PRESS, AMERICAN INSTITUTE OF PHYSICS, WOODBURY, NY 11797-2999 (Stati Uniti d'America)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Pasqualotto R.; Sardella A.; Intravaia A.; Marrelli L. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- 12th Topical Conference on High-Temperature Plasma Diagnostics, PRINCETON, NEW JERSEY, JUN 07-11, 1998.
La rivista è pubblicata anche online con ISSN 1089-7623. (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://biblioproxy.cnr.it:2161/resource/1/rsinak/v70/i2/p1416_s1 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- Scopu (literal)
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Pasqualotto R. (Reprint Author), Consorzio RFX, Padua, Italy. Consorzio RFX, Padua, Italy. (literal)
- Titolo
- Improved performance of the Thomson scattering system in RFX (literal)
- Abstract
- A Thomson scattering diagnostic is used in the RFX reversed field pinch experiment to measure single pulse, multipoint electron temperature (T-e) profiles. Recent significant improvements have provided reliable and routine operation of the diagnostic. Custom developed CAMAC charge analog-to-digital converters have been introduced, which sample the plasma light 170 ns after the laser light and have greater sensitivity. The spectrometer configuration and the calibration procedure have been optimized. These upgrades have finally led to better fitted scattering spectra and more regular estimates of T-e profiles, allowing the measurement of temperatures as low as 20 eV. The introduction of a second spectrometer has recently added a further ten positions to the original ten point profile, resolving the often steep T-e edge gradient. On axis values are in good agreement with other T-e measurements from SXR diagnostics (either SiLi and double filter method). T-e profiles are typically rather flat, but some dependence on the plasma parameters, like density and pinch parameter, has been drawn. Significant T-e profile modifications have been observed during transient events like pulsed poloidal current drive and pellet injection. The diagnostic will be completed soon, allowing production of 27 point profiles, with the introduction of the third spectrometer. Double pulse operation of the laser is in progress. (C) 1999 American Institute of Physics. [S0034-6748(99)69401-1]. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di