http://www.cnr.it/ontology/cnr/individuo/prodotto/ID245710
A first experimental comparison between the Schroeder's backintegration method and a new method based on sound intensity for measuring reverberation time. (Abstract/Comunicazione in rivista)
- Type
- Label
- A first experimental comparison between the Schroeder's backintegration method and a new method based on sound intensity for measuring reverberation time. (Abstract/Comunicazione in rivista) (literal)
- Anno
- 1992-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1121/1.403368 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Domenico Stanzial and Eleonora Carletti (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- PACS
43.55.Br
Room acoustics: theory and experiment; reverberation, normal modes, diffusion, transient and steady-state response
43.58.Fm
Sound level meters, level recorders, sound pressure, particle velocity, and sound intensity measurements, meters, and controllers (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://asadl.org/jasa/resource/1/jasman/v91/i4/p2368_s3 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- Google Scholar (literal)
- Comunicazione (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Cemoter, Natl. Res. Council of Italy, Via Canal Bianco 28, I-44044 Cassana, Ferrara, Italy (literal)
- Titolo
- A first experimental comparison between the Schroeder's backintegration method and a new method based on sound intensity for measuring reverberation time. (literal)
- Abstract
- A new method based on the experimental evaluation of the energy transfer function of an enclosed space from sound intensity measurements has been experimentally compared with the well-known method of measuring reverberation time due to Schroeder [M. R. Schroeder, J. Acoust. Soc. Am. 37, 409-412 (1965)]. The measurements of active and reactive sound intensity were carried out by a B&K 2133 real time frequency analyzer and the reverberation time was computed using the built-in reverbBack user defined function over a pressure input multispectrum. As the transfer function is simply related to the reverberation time through an Eyring-like formula [D. Stanzial, J. Acoust. Soc. Am. Suppl. 1 88, S185 (1990)] the comparison gives a first experimental confirmation of the intensimetric approach to reverberation time evaluation. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave