http://www.cnr.it/ontology/cnr/individuo/prodotto/ID24333
Impact of the use of attenuation correction in G-SPECT myocardial perfusion imaging interpretation: results of multicenter SPAG (Spect Attenuation-correction vs Gated) study (Articolo in rivista)
- Type
- Label
- Impact of the use of attenuation correction in G-SPECT myocardial perfusion imaging interpretation: results of multicenter SPAG (Spect Attenuation-correction vs Gated) study (Articolo in rivista) (literal)
- Anno
- 2010-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1007/s00259-011-1855-4 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Genovesi D.; Giorgetti A.; Gimelli A.; Cannizzaro G.; Giubbini R.; Bertagna F.; Fagioli G.; Rossi M.; Romeo A.; Bertolaccini P.; Bonini R.; Ferdeghini E. M.; Marzullo P. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
- In: European Journal of Nuclear Medicine and Molecular Imaging. Abstract, vol. 37 pp. S372 - S372. Springer, 2010. (literal)
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Fondazione G. Monasterio Pisa, \"V. Cervello\" Hospital, Palermo, Italy, Spedali Civili, Brescia, Ospedale Maggiore, Bologna, Ospedale Ss Giacomo e Cristoforo, Massa, CNR-IFC, Pisa (literal)
- Titolo
- Impact of the use of attenuation correction in G-SPECT myocardial perfusion imaging interpretation: results of multicenter SPAG (Spect Attenuation-correction vs Gated) study (literal)
- Abstract
- In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD).
We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI > 27 were considered \"overweight\". Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data.
In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p < 0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p < 0.05). (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di