Identification and dosage of 2-Furaldehyde and 5-Hydroxymethyl-2-Furaldehyde in beverage by reversed phase chromatography with a microbore column (Articolo in rivista)

Type
Label
  • Identification and dosage of 2-Furaldehyde and 5-Hydroxymethyl-2-Furaldehyde in beverage by reversed phase chromatography with a microbore column (Articolo in rivista) (literal)
Anno
  • 1996-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1080/10826079608006315 (literal)
Alternative label
  • Isabella Nicoletti, Claudio Corradini, Eugenia Cogliandro, Danilo Corradini (1996)
    Identification and dosage of 2-Furaldehyde and 5-Hydroxymethyl-2-Furaldehyde in beverage by reversed phase chromatography with a microbore column
    in Journal of liquid chromatography & related technologies (Print)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Isabella Nicoletti, Claudio Corradini, Eugenia Cogliandro, Danilo Corradini (literal)
Pagina inizio
  • 1241 (literal)
Pagina fine
  • 1254 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 19 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 14 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 8 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopus (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR Istituto di Cromatografia (literal)
Titolo
  • Identification and dosage of 2-Furaldehyde and 5-Hydroxymethyl-2-Furaldehyde in beverage by reversed phase chromatography with a microbore column (literal)
Abstract
  • This paper reports the results of a study performed to develop a rapid and straightforward chromatographic method for the identification and dosage of 5-hydroxymethyl-2-fbraldehyde (HMF) and 2-furaldehyde (FA), which are recognized indices of deteriorative changes in commercially processed food. The method employs a Supelco microbore reversed phase column (300 x 1.0 mm I.D.), eluted isocratically with a 94:6 (vh) water/acetonitrile mixture at flow rate of 60 pL/min. Sample is detected at 280 nm in a micro flow cell of 300 nl. Peak purity and identification is assessed by comparing the UV spectra monitored at two points through the chromatographic peak in continuous flow mode in the range fiom 200 to 400 nm. This method is successfully applied to the identification and quantitative determination of HMF and FA in alcoholic and nonalcoholic beverages by an internal standard method without any sample pretreatment (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it