Power-Line Communication in Medium-Voltage System: Simulation Model and On field Experimental Tests (Articolo in rivista)

Type
Label
  • Power-Line Communication in Medium-Voltage System: Simulation Model and On field Experimental Tests (Articolo in rivista) (literal)
Anno
  • 2012-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1109/TPWRD.2011.2171009 (literal)
Alternative label
  • A. Cataliotti; Di Cara; R. Fiorelli; G. Tinè (2012)
    Power-Line Communication in Medium-Voltage System: Simulation Model and On field Experimental Tests
    in IEEE transactions on power delivery; IEEE - Institute of Electrical and Electronics Engineers, Piscataway, N.J. (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • A. Cataliotti; Di Cara; R. Fiorelli; G. Tinè (literal)
Pagina inizio
  • 62 (literal)
Pagina fine
  • 69 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • Q1 (Quartile rivista) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6070996 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 27 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 8 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 1 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopu (literal)
  • oogle Scholar (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • ISSIA UOS PALERMO DIEETCAM UNIVERSITA' PALERMO ST MICROELECTRONICS (literal)
Titolo
  • Power-Line Communication in Medium-Voltage System: Simulation Model and On field Experimental Tests (literal)
Abstract
  • The aim of this paper is to develop a complete model of a power-line communication (PLC) system operating on a medium-voltage (MV) network. The core-shield configuration was chosen for signal transmission in the power cables. In order to validate the developed model experimental, the medium-voltage network of the Favignana island was used to carry out detailed testing. The transmission was performed between two transformer substations in the presence of mains voltage (i.e., 24 kV). ST7540 FSK power-line transceivers, together with capacitive coupling interfaces, were used for the transmission and the reception of the communication signal. The correlation between the experimental measurements and the simulation results would appear to validate the use of the developed model for the analysis of MV transmission channels. (literal)
Editore
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
Insieme di parole chiave di
data.CNR.it