http://www.cnr.it/ontology/cnr/individuo/prodotto/ID187776
An investigation of SIMS matrix effects on H, Li and B ionization in tourmaline (Articolo in rivista)
- Type
- Label
- An investigation of SIMS matrix effects on H, Li and B ionization in tourmaline (Articolo in rivista) (literal)
- Anno
- 1999-01-01T00:00:00+01:00 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Ottolini L. 1; Hawthorne F.C. 2; (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1. CNR, Ctr Studio Cristallochim & Cristallografia, I-27100 Pavia, Italy;
2. Univ Manitoba, Dept Geol Sci, Winnipeg, MB R3T 2N2, Canada. (literal)
- Titolo
- An investigation of SIMS matrix effects on H, Li and B ionization in tourmaline (literal)
- Abstract
- A SIMS procedure has been developed to quantify H, Li and B in schorl-elbaite series tourmalines. It relies on the use of calibration curves determined from various tourmaline standards, mainly characterized by crystal-structure refinement (SREF) and electron-microprobe analysis (EMPA). The SIMS data have allowed us to investigate matrix effects on H, Li and B ionization (with Si and Al assumed, in turn, as the matrix-reference element), and to test the accuracy of our general calibration curves, previously developed for silicates. In particular, the H/Si as well as H/Al ionization behaviour are not indicative of significant residual matrix effects; the agreement between SIMS and reference data is mostly within the reproducibility of analysis (2 sigma), and for all samples is within 10%. The IY(Li/Si) and IY(Li/Al) are affected by matrix effects possibly related to the different (Fe+Mn) and/or (Si+Al) content of the sample. Since the maximum variation in terms of chemical composition in these matrices concerns Fe and Mn concentrations, we used at a first approximation (Fe+Mn) content to investigate the IY(Li) variation among the various samples. A linear regression: IY(Li/Si) (or similarly, IY(Li/Al)) vs. (Fel-Mn) (cat %) was obtained and used to improve the accuracy of analysis. All the experimental IY(LI) agree with the expected values within 13% rel. (in one case: 24% rel.), mostly comparable to the uncertainty of Li estimation in these matrices. We can pessimistically put the uncertainty of our regression lines for Li at 15-20% rel. The IY(B/Si) and IY(B/Al) seem to be affected, although to a lower extent than Li, by the same kind of matrix effects, the maximum variation of IY(B) being similar to 10-12%. Accurate B analyses, better than 3% rel., can be obtained by calibrating IY(B) vs. (Fe+Mn) content of each sample. A few examples of this procedure testify the possibility to use this approach to achieve accurate data for H, Li and B by SIMS in schorl-elbaitic tourmaline samples. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di