Treatment of EXAFS data taken in the fluorescence mode in non-linear conditions (Articolo in rivista)

Type
Label
  • Treatment of EXAFS data taken in the fluorescence mode in non-linear conditions (Articolo in rivista) (literal)
Anno
  • 2004-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1107/S0909049504002122 (literal)
Alternative label
  • Ciatto, G (Ciatto, G); d'Acapito, F (d'Acapito, F); Boscherini, F (Boscherini, F); Mobilio, S (Mobilio, S) (2004)
    Treatment of EXAFS data taken in the fluorescence mode in non-linear conditions
    in Journal of synchrotron radiation
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Ciatto, G (Ciatto, G); d'Acapito, F (d'Acapito, F); Boscherini, F (Boscherini, F); Mobilio, S (Mobilio, S) (literal)
Pagina inizio
  • 278 (literal)
Pagina fine
  • 283 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 11 (literal)
Rivista
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1. European Synchrotron Radiat Facil, CNR, Glida CRG, F-38043 Grenoble, France 2. European Synchrotron Radiat Facil, INFM, Gilda CRG, F-38043 Grenoble, France 3. Univ Bologna, INFM, I-40127 Bologna, Italy 4. Univ Bologna, Dept Phys, I-40127 Bologna, Italy 5. Univ Roma Tre, Dept Phys, I-00146 Rome, Italy 6. INFM, LNF, I-00044 Frascati, Italy (literal)
Titolo
  • Treatment of EXAFS data taken in the fluorescence mode in non-linear conditions (literal)
Abstract
  • The aim of this work is to investigate the possibility of extracting correct structural parameters from fluorescence EXAFS data taken at high count rates with an energy-resolving detector. This situation is often encountered on third-generation synchrotron radiation sources which provide a high flux on the sample. Errors caused by pulse pile-up in the extraction of structural information have been quantified in a real experiment, and different approaches to the problem of data correction have been elaborated. The different approaches are discussed in a comparison of the ability of each kind of correction to recover the correct structural parameters. The result of our analysis is that it is possible to work in non-linear conditions and correct the data, if the response of the acquisition system is known. Reliable structural information can be obtained with data acquired up to a count rate equal to approximately 60% of the inverse of the dead time. (literal)
Prodotto di
Autore CNR

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi