http://www.cnr.it/ontology/cnr/individuo/prodotto/ID175285
Problems of determining true equilibrium pressures of hydrogen getters over a wide range of getter temperature and hydrogen sorption (Articolo in rivista)
- Type
- Label
- Problems of determining true equilibrium pressures of hydrogen getters over a wide range of getter temperature and hydrogen sorption (Articolo in rivista) (literal)
- Anno
- 1999-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1116/1.582082 (literal)
- Alternative label
F. Ghezzi; M. De Angeli (1999)
Problems of determining true equilibrium pressures of hydrogen getters over a wide range of getter temperature and hydrogen sorption
in Journal of vacuum science & technology. A. Vacuum, surfaces, and films
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- F. Ghezzi; M. De Angeli (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://avspublications.org/jvsta/resource/1/jvtad6/v17/i6/p3452_s1 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Istituto di Fisica del Plasma - CNR (literal)
- Titolo
- Problems of determining true equilibrium pressures of hydrogen getters over a wide range of getter temperature and hydrogen sorption (literal)
- Abstract
- We have assessed a conventionally configured apparatus to measure hydrogen equilibrium pressures of getter alloys over the temperature range of 25 to 400 °C and hydrogen concentration range of 0.02 to 1 H/A. An in situ approach has been proposed to correlate the measurements of different gauges using one of the precisely calibrated gauges as a standard reference. The pressure range of interest was 10-7-105 Pa and was covered using a Bayart-Alpert gauge, a spinning rotor gauge, and different capacitance gauges. The approach involves measuring the characteristic response of these instruments prior to determining hydrogen equilibrium pressures over the relevant range of wall and getter bed temperature. To evaluate the accuracy of the measurements, we performed an error propagation analysis. The use of a porous filter to avoid fines contamination and the adsorption/desorption kinetics of the walls of the system were both addressed. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di