Characterization of BSA unfolding and aggregation using a Single-Capillary Viscometer and Dynamic Surface Tension Detector (Articolo in rivista)

Type
Label
  • Characterization of BSA unfolding and aggregation using a Single-Capillary Viscometer and Dynamic Surface Tension Detector (Articolo in rivista) (literal)
Anno
  • 2011-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.talanta.2011.08.009 (literal)
Alternative label
  • Bramanti Emilia [ 1 ]; Ferrari Carlo [ 2 ]; Angeli Valeria [ 1 ], Onor Massimo [ 1]; Synovec Robrt E. [ 3 ] (2011)
    Characterization of BSA unfolding and aggregation using a Single-Capillary Viscometer and Dynamic Surface Tension Detector
    in Talanta (Oxf.)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Bramanti Emilia [ 1 ]; Ferrari Carlo [ 2 ]; Angeli Valeria [ 1 ], Onor Massimo [ 1]; Synovec Robrt E. [ 3 ] (literal)
Pagina inizio
  • 2553 (literal)
Pagina fine
  • 2561 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 85 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 5 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • [ 1 ] Ist Chim Composti Organo Metall ICCOM UOS Pisa, CNR, Natl Res Council Italy, Area Ric, I-56124 Pisa, Italy [ 2 ] INO UOS Pisa, Ist Nazl Ott, CNR, Natl Res Council Italy,Area Ric, I-56124 Pisa, Italy [ 3 ] Univ Washington, Ctr Proc Analyt Chem, Dept Chem, Seattle, WA 98195 USA (literal)
Titolo
  • Characterization of BSA unfolding and aggregation using a Single-Capillary Viscometer and Dynamic Surface Tension Detector (literal)
Abstract
  • A dynamic surface tension detector (DSTD) has been equipped with an additional pressure sensor for simultaneous viscosity measurements, as a detector for flow injection analysis. The viscosity measurement is based on a single capillary viscometer (SCV) placed in parallel configuration with the DSTD. The viscometer in the optimized conditions consists of a PEEK capillary (i.d.=0.25 mm, L=75 cm) kept at constant temperature using a thermostatic bath, which leads on the two sides to the two arms of a differential piezoelectric pressure transducer with a range of 0-35 psi. The DSTD, described previously, measures the changing pressure across the liquid/air interface of 2 mu L. drops repeatedly forming at the end of a capillary. SCV performance has been evaluated by measuring dynamic viscosity of water/glycerol mixtures analysed in flow injection and comparing the results with the values reported in the literature. The detection limits of SCV and DSTD, calculated as 3 sigma of the blank, were 0.012 cP and 0.6 dyn cm(-1), respectively. The Fl-SCV-DSTD system has been applied to the study of temperature-induced denaturation/aggregation process in bovine serum albumin (BSA). The results have been supported and discussed with respect to BSA conformational analysis performed using Fourier Transform infrared spectroscopy. (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it