http://www.cnr.it/ontology/cnr/individuo/prodotto/ID170142
Atomic force microscopy and transmission electron microscopy analyses of low-temperature laser welding of the cornea (Articolo in rivista)
- Type
- Label
- Atomic force microscopy and transmission electron microscopy analyses of low-temperature laser welding of the cornea (Articolo in rivista) (literal)
- Anno
- 2009-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1007/s10103-008-0617-4 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Matteini P.; Sbrana F.; Tiribilli B.; Pini R. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
- Pubblicato online 04.11.2008
DOI 10.1007/s10103-008-0617-4 Springer. DOI 10.1007/s10103-008-0617-4 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Google Scholar (literal)
- Scopu (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1) Istituto di Fisica Applicata, Consiglio Nazionale delle Ricerche, 50019, Sesto Fiorentino, Italy
2) Centro Interdipartimentale per lo Studio di Dinamiche Complesse (CSDC), Dipartimento di Fisica, Università di Firenze, Sesto Fiorentino, Italy
3) Istituto dei Sistemi Complessi, Consiglio Nazionale delle Ricerche, Sesto Fiorentino, Italy (literal)
- Titolo
- Atomic force microscopy and transmission electron microscopy analyses of low-temperature laser welding of the cornea (literal)
- Abstract
- Low-temperature laser welding of the cornea is a
technique used to facilitate the closure of corneal cuts. The
procedure consists of staining the wound with a chromophore
(indocyanine green), followed by continuous wave
irradiation with an 810 nm diode laser operated at low
power densities (1216 W/cm2), which induces local
heating in the 5565 °C range. In this study, we aimed to
investigate the ultrastructural modifications in the extracellular
matrix following laser welding of corneal wounds by
means of atomic force microscopy and transmission electron
microscopy. The results evidenced marked disorganization
of the normal fibrillar assembly, although collagen appeared
not to be denatured under the operating conditions we
employed. The mechanism of low-temperature laser welding
may be related to some structural modifications of the
nonfibrillar extracellular components of the corneal stroma. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di