http://www.cnr.it/ontology/cnr/individuo/prodotto/ID16882
Recent advances in the assessment of the ratios of cortisol to cortisone and of some of their metabolites in urine by LC-MS-MS (Articolo in rivista)
- Type
- Label
- Recent advances in the assessment of the ratios of cortisol to cortisone and of some of their metabolites in urine by LC-MS-MS (Articolo in rivista) (literal)
- Anno
- 2009-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1002/jms.1530 (literal)
- Alternative label
Saba A., Raffaelli A., Cupisti A., Petri A., Marcocci C., Salvadori P. (2009)
Recent advances in the assessment of the ratios of cortisol to cortisone and of some of their metabolites in urine by LC-MS-MS
in Journal of mass spectrometry (Print)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Saba A., Raffaelli A., Cupisti A., Petri A., Marcocci C., Salvadori P. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- CNR-ICCOM Sezione di Pisa; Dipartimento di Chimica e Chimica Industriale, Dipartimento di Medicina Interna, Divisione di Nefrologia, Dipartimento di Endocrinologia e Metabolismo, Ortopedia e Traumatologia, Medicina del Lavoro e AmbiSEN-Environmental and Endocrine and Nervous SystemHigh Technology
for the Study of the Effects of Harmful Agents, Università di Pisa (literal)
- Titolo
- Recent advances in the assessment of the ratios of cortisol to cortisone and of some of their metabolites in urine by LC-MS-MS (literal)
- Abstract
- A previously reported method for the assessment of the ratio of tetrahydrocortisol (THF) + allo-tetrahydrocortisol (A-THF) to tetrahydrocortisone (THE) by HPLC-MS-MS has been significantly improved, in order to increase either ruggedness and reliability. That was achieved by the introduction of an on-line sample cleanup stage, whichmade use of a perfusion column as a solid phase microextraction (SPE) cartridge. The set of analytes was expanded, by introducing cortisol and cortisone, whose ratio supply additional diagnostic information. The response factors of both THF and A-THF has been checked, resulting almost
identical, as well as the influence of the matrix on the calibration curves which, although different for water and urine, had similar effect on the ratios of interest. As a consequence, the calibration solutions can be prepared in pure water. The influence of several different storage procedures has also been tested, resulting in no substantial effect on the final result. Finally, the improved method has been used to run real samples fromhealthy volunteers,with satisfactory results. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di