http://www.cnr.it/ontology/cnr/individuo/prodotto/ID128794
Integrated membrane system for pure hydrogen production: a Pd-Ag membrane reactor and a PEMFC (Articolo in rivista)
- Type
- Label
- Integrated membrane system for pure hydrogen production: a Pd-Ag membrane reactor and a PEMFC (Articolo in rivista) (literal)
- Anno
- 2011-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.fuproc.2010.09.023 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Brunetti A., Barbieri G. Drioli E. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- Abstract (literal)
- Scopu (literal)
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1Institute on Membrane Technology (ITM-CNR), National Research Council, c/o The University of Calabria, Cubo 17C, Via Pietro BUCCI, 87036 Rende CS, Italy
2Department of Chemical Engineering and Materials, The University of Calabria, Cubo 44A, Via Pietro BUCCI, 87036 Rende CS, Italy (literal)
- Titolo
- Integrated membrane system for pure hydrogen production: a Pd-Ag membrane reactor and a PEMFC (literal)
- Abstract
- In this work, an integrated system consisting of single stage hydrogen production and a commercial PEMFC
was investigated experimentally. The CO-free hydrogen fed to the PEMFC was produced in a Pd-Ag
membrane reactor (MR), upgrading a syngas stream with a composition similar to that coming out of a
reformer (CO 45%; H2 50%; CO2 4%; N2 balance, on dry basis). The performance of the MR was evaluated in
terms of CO conversion and H2 recovery as a function of the feed pressure (up to 600 kPa) and space velocity;
no sweep gas was used for promoting the H2 permeation, since this role was assigned exclusively to the feed
pressure.
Special attention was paid to the analysis of the integrated system, focusing on the influence of the Pd-Ag MR
operating conditions on the electrical performance of the PEMFC. The PEMFC internal crossover was also
considered to have an effect on the electrical performance and this was taken into account estimating the
PEMFC actual efficiency. Furthermore, the chemical efficiency of the integrated membrane plant was
evaluated, considering the H2 converted into electricity with respect to the total amount of H2 contained in
the feed mixture. An interesting performance was shown by the integrated system since the PEMFC
performance was close to the power nominal value. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di