http://www.cnr.it/ontology/cnr/individuo/prodotto/ID109860 
					Design and specifications of the diagnostics for the instrumented calorimeter of SPIDER (Abstract/Poster in atti di convegno)
- Type
 - Label
 - Design and specifications of the diagnostics for the instrumented calorimeter of SPIDER (Abstract/Poster in atti di convegno) (literal)
 
- Anno
 - 2011-01-01T00:00:00+01:00 (literal)
 
- Alternative label
 De Muri M.; Dalla Palma M.; Fasolo D.; Pasqualotto R.; Pomaro N.; Rizzolo A.; Serianni G.; Tollin M. (2011)
Design and specifications of the diagnostics for the instrumented calorimeter of SPIDER
in 14th International Conference on Ion Sources (ICIS11), Giardini Naxos, Messina, September 12 - 16, 2011
 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
 - De Muri M.; Dalla Palma M.; Fasolo D.; Pasqualotto R.; Pomaro N.; Rizzolo A.; Serianni G.; Tollin M. (literal)
 
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
 - PM 11; Proc. to be published in Review on Scientific Instruments. This work was set up in collaboration and financial support of F4E. (literal)
 
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
 - http://icis11.lns.infn.it/BoA.pdf (literal)
 
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
 - http://icis11.lns.infn.it/BoA.pdf PM11 (literal)
 
- Note
 - Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
 - 1 Consorzio RFX, Euratom-ENEA association, Corso Stati Uniti 4, 35127 Padova, Italy; 
2  Dipartimento di Ingegneria Elettrica, Padova University, Via Gradenigo, 6/A - 35131 Padova, Italy.
(M.De Muri 1,2, M.Dalla Palma 1, D.Fasolo 1, R.Pasqualotto 1, N. Pomaro 1, A.Rizzolo 1, G. Serianni 1, M. Tollin 1) (literal)
 
- Titolo
 - Design and specifications of the diagnostics for the instrumented calorimeter of SPIDER (literal)
 
- Abstract
 - Operation of the thermonuclear fusion experiment ITER requires additional heating via injection 
of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction in 
Padova, the production of negative ions will be studied and  optimised. This test bed will aim at 
assessing beam characteristics and verifying the source proper operation. 
STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic used to 
characterise the SPIDER beam during short operation (several seconds) to verify if the beam meets 
the ITER requirement about the maximum allowed beam non-uniformity (below ±10%). During 
long pulse operations, STRIKE is parked off-beam in the vacuum vessel. The most important 
measurements performed by STRIKE  are beam uniformity, beamlet divergence and stripping 
losses. 
This contribution gives an overview of the diagnostics dedicated to these measurements: thermal 
cameras to measure the temperature pattern on the rear side of the tiles; current sensors to measure 
the current associated to the beam particles; thermocouples, giving a local temperature 
measurement, to provide a calibration for thermal cameras; electrostatic sensors to characterise the 
plasma formed by the interaction of the beam with the background  gas. In order to prevent 
secondary electrons from escaping the tile surface, a voltage is applied to the tiles with respect to 
the vacuum vessel. 
The specifications of these diagnostics have been defined according to the results of electrostatic 
and thermal simulations. 
A failure modes and effects analysis has been performed during the design. Consequently the 
project of the STRIKE diagnostics has been optimized to reduce the possible failure risks. 
This work was set up in collaboration and financial support of F4E. (literal)
 
- Prodotto di
 - Autore CNR
 
Incoming links:
- Autore CNR di
 - Prodotto