Absorption into fluorescence. A method to sense biologically relevant gas molecules. (Articolo in rivista)

Type
Label
  • Absorption into fluorescence. A method to sense biologically relevant gas molecules. (Articolo in rivista) (literal)
Anno
  • 2011-01-01T00:00:00+01:00 (literal)
Alternative label
  • Strianese M, Varriale A, Staiano M, Pellecchia C, D'Auria S. (2011)
    Absorption into fluorescence. A method to sense biologically relevant gas molecules.
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Strianese M, Varriale A, Staiano M, Pellecchia C, D'Auria S. (literal)
Pagina inizio
  • 298 (literal)
Pagina fine
  • 302 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 3 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Titolo
  • Absorption into fluorescence. A method to sense biologically relevant gas molecules. (literal)
Abstract
  • In this work we present an innovative optical sensing methodology based on the use of biomolecules as molecular gating nano-systems. Here, as an example, we report on the detection of analytes related to climate change. In particular, we focused our attention on the detection of nitric oxide (NO) and oxygen (O(2)). Our methodology builds on the possibility of modulating the excitation intensity of a fluorescent probe used as a transducer and a sensor molecule whose absorption is strongly affected by the binding of an analyte of interest used as a filter. The two simple conditions that have to be fulfilled for the method to work are: (a) the absorption spectrum of the sensor placed inside the cuvette, and acting as the recognition element for the analyte of interest, should strongly change upon the binding of the analyte and (b) the fluorescence dye transducer should exhibit an excitation band which overlaps with one or more absorption bands of the sensor. The absorption band of the sensor affected by the binding of the specific analyte should overlap with the excitation band of the transducer. The high sensitivity of fluorescence detection combined with the use of proteins as highly selective sensors makes this method a powerful basis for the development of a new generation of analytical assays. Proof-of-principle results showing that cytochrome c peroxidase (CcP) for NO detection and myoglobin (Mb) for O(2) detection can be successfully used by exploiting our new methodology are reported. The proposed technology can be easily expanded to the determination of different target analytes. (literal)
Prodotto di
Autore CNR

Incoming links:


Autore CNR di
Prodotto
data.CNR.it