The Analysis of Explosion of Storage Plants Containing Display Pyrotechnics (Contributo in atti di convegno)
- Type
- Label
- The Analysis of Explosion of Storage Plants Containing Display Pyrotechnics (Contributo in atti di convegno) (literal)
- Anno
- 2010-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.4405/ptse2010.P1.15 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Basco A.; Salzano E. (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
- doi: 10.4405/ptse2010.P1.15 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Istituto Ricerche sulla Combustione - CNR - Napoli, Italy (literal)
- Titolo
- The Analysis of Explosion of Storage Plants Containing Display Pyrotechnics (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
- 978-88-88104-11-9 (literal)
- Abstract
- Several relevant accidents involving fireworks storage, as the explosion occurred in Enschede
(NL) in 2000 or in Denmark in 2004, have induced significant modification in the Seveso
(2003/105/CE) and pyrotechnic Directives (2007/23/EC), which now include firework storage
plants other than manufacturing installations as relevant risk industries. However, despite the
large number of storage plants in Europe and worldwide, few and un-detailed guidelines for
risk assessment of storage plants can be found in the open literature.
The most essential references about the use and storage of fireworks are NFPA1124,
NFPA1123, NFPA1126. These guidelines give several information on safety distances and
recommendation for manipulation of explosives and fireworks whereas storage design and
risk assessment guidelines are neglected, although NFPA1124 gives indication on separation
distances among storage system containing large amount of explosives (up to 40,000 kg), and
civilian building (minimum distance: 600 m), public highways (300 m), barricaded (50 m)
and un-barricaded (100 m) storage container. Military standards (TM 5-855; TM 5-1300, TM
9-1300-214) are also scarcely useful for risk assessment when low-energy pyrotechnics
(fireworks) are of concern. Eventually, the aim of this work is the assessment of risk in the
storage plant of large amount of pyrotechnics or secondary explosives in underground and
aboveground, either reinforced or low-strength structures, with specific reference to the
pressure wave generated by the explosion. (literal)