Use of cavitands as selective adsorbing materials in GC-like air quality monitoring microsystem (Contributo in atti di convegno)

Type
Label
  • Use of cavitands as selective adsorbing materials in GC-like air quality monitoring microsystem (Contributo in atti di convegno) (literal)
Anno
  • 2006-01-01T00:00:00+01:00 (literal)
Alternative label
  • Zampolli S; Elmi I; Cardinali GC; Severi M; Dalcanale E; Betti P (2006)
    Use of cavitands as selective adsorbing materials in GC-like air quality monitoring microsystem
    in 11th Italian Conference on Sensors and Microsystems, Lecce, 8-10/02/2006
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Zampolli S; Elmi I; Cardinali GC; Severi M; Dalcanale E; Betti P (literal)
Pagina inizio
  • 222 (literal)
Pagina fine
  • 226 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • The conference presentation of this proceeding was awarded with the \"Angelo Rizzo price for the best oral presentation\" at the 11th Italian Conference on Sensors and Microsystems (scan of the award is attached). (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://ebooks.worldscinet.com/ISBN/9789812793393/9789812793393_0044.html (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
  • Sensors and Microsystems - 11th Italian Conference (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR-IMM - Institute for Microelectronics and Microsystems, CNR - National Research Council, Bologna, Italy Department of Organic and Industrial Chemistry, University of Parma, Parma, Italy (literal)
Titolo
  • Use of cavitands as selective adsorbing materials in GC-like air quality monitoring microsystem (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 981-279-338-0 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autoriVolume
  • Siciliano P; Capone S; Di Natale C; D'Amico A (literal)
Abstract
  • The use of cavitands as innovative pre-concentration materials for outdoor air quality monitoring applications was studied. With respect to conventional adsorbing materials, cavitands feature lower desorption temperatures and a selective pre-concentration behaviour due to the specificity of the host-guest interactions. These characteristics make them particularly suitable for integration in simplified GC-like gas sensing systems based on micromachined components. The detection limit of a miniaturized GC system with a MOX sensor used as detector will be reported. (literal)