Automatic Vertebral Morphometry Assessment (Contributo in atti di convegno)

Type
Label
  • Automatic Vertebral Morphometry Assessment (Contributo in atti di convegno) (literal)
Anno
  • 2007-01-01T00:00:00+01:00 (literal)
Alternative label
  • Casciaro S.; Massoptier L. (2007)
    Automatic Vertebral Morphometry Assessment
    in IEEE EMBC 2007 (29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society), Lyon, France, 23-26 Agosto 2007
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Casciaro S.; Massoptier L. (literal)
Pagina inizio
  • 5571 (literal)
Pagina fine
  • 5574 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
  • Proceedings of the 29th Annual International Conference of the IEEE EMBS (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
  • In: IEEE EMBC 2007 (29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society) (Lyon, France, 23-26 Agosto 2007). Proceedings, pp. 5571 - 5574. IEEE Service Center, 2007. (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 4 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#descrizioneSinteticaDelProdotto
  • ABSTRACT: Diagnosis of vertebral deformation and fracture is a key issue in the management of osteoporosis. Vertebral morphometry is the key solution to assess these vertebral deformities, but it is a tedious operation for the rheumatologist. In this paper, we propose an automatic approach to localize vertebrae and determine the vertebral morphometry. Based on a local phase symmetry measure, our approach shows promising results even on poor quality images. This work was tested on 22 scans of conventional lateral X-rays radiographs and compared to the results obtained by a trained radiologist. It resulted to have acceptable low error rates for localization and vertebral morphometry measures, but with a lack of robustness among images. Amelioration is necessary for images with an unoptimized patient positioning, when the X-ray beam is not perpendicular to the spine. (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Division of Biomedical Engineering Science and Technology, Institute of Clinical Physiology, Lecce, Italy (literal)
Titolo
  • Automatic Vertebral Morphometry Assessment (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 1-4244-0788-5 (literal)
Abstract
  • Diagnosis of vertebral deformation and fracture is a key issue in the management of osteoporosis. Vertebral morphometry is the key solution to assess these vertebral deformities, but it is a tedious operation for the rheumatologist. In this paper, we propose an automatic approach to localize vertebrae and determine the vertebral morphometry. Based on a local phase symmetry measure, our approach shows promising results even on poor quality images. This work was tested on 22 scans of conventional lateral X-rays radiographs and compared to the results obtained by a trained radiologist. It resulted to have acceptable low error rates for localization and vertebral morphometry measures, but with a lack of robustness among images. Amelioration is necessary for images with an unoptimized patient positioning, when the X-ray beam is not perpendicular to the spine. (literal)